HP StorageWorks P9000 Disk Array Plug-in Software for Oracle Enterprise Manager Integration Guide (5697-0837, March 2011)

Table 5 Report error messages (continued)
Description and solutionError
This error appears when the plug-in cannot find any
command devices presented to the plug-in host.
No command device (CMD device) found to monitor the
array.
For any internal errors, contact your HP service
representative and provide the error codes.
Internal Error
Missing mapping information in the mapping reports
“Error message descriptions and solutions (page 27) provides solutions on how to solve incorrect
report information.
Table 6 Error message descriptions and solutions
Description and solutionError
Read permission has not been assigned on corresponding
OS device special files. Give read permission to device
special files.
NOTE: Even if the logical volume groups or ASM is used,
read permission needs to be given to the device special
files that are used for creating these logical volume groups.
LUN mapping information is missing in the mapping
reports.
Click GO to refresh the reports with the filter changes (see
“Reports” (page 12)).
The filter selections are not appearing in the reports
Report generation performance
If the OMS is slow in generating reports, adjust the optimizer parameters of the EMREP database.
See the Oracle database documentation on fine tuning for more information.