HP StorageWorks P9000 Application Performance Extender Software User Guide (5697-0984, September 2012)

Recommended actionsProblem/Scenario
1. On the Controller Settings screen, select the array that was controlled
by the controller that rebooted.
2. Remove the controller associated with the array.
3. Select another controller for the same array that is available from the
Controller(s) And Managed Array(s) Information table.
4. On the Controller Settings screen, under Command Device Settings,
select an array from the Select Array list.
5. Select a command device from the Command Device Settings table
to configure the command device of the host running the controller.
6. Set Command devices and provide authentication information if ne-
cessary.
7. Specify DLOM settings.
8. Select the SLO Profile that was previously assigned to that array and
apply it again.
Scenario: Manual controller
failover procedure
Verify that the remote CIM Client connection is enabled on ESX server.
To enable it, perform the following steps
1. vi /etc/sfcb/sfcb.cfg
2. Look for httpLocalOnly: true and change this to httpLoc-
alOnly: false
3. Execute service sfcbd-watchdog restart or/etc/init.d/
sfcbd-watchdog restart
Unable to add VMWare ESX
servers and the following error is
seen in the message panel: Could
not connect to CIMOM on
ESX Server “x.x.x.x”
.
1. Ensure that the NPIV is active on the ESX server. You can verify this
by seeing the entry in the /proc/scsi/qla2xxx/# file or in the
fabric switch.
2. Run service sfcbd-watchdog restart or/etc/init.d/
sfcbd-watchdog restart.
3. Run collect configuration data from APEX GUI for that ESX server.
APEX is not showing ESX guest in
Workload addition screen.
HP StorageWorks P9000 Application Performance Extender Software User Guide 95