Hitachi Dynamic Link Manager Software Users Guide for AIX

Table Of Contents
into the integrated trace files. To save as much information as possible,
change the settings for Hitachi Network Objectplaza Trace Library, increasing
the integrated trace file size and buffer size. Note that if the values are too
large, it will place a heavy load on the system. When determining these
values, be sure to consider these operational tradeoffs.
The following table lists the default values and recommended values for the
integrated trace file setting.
Table 3-18 Default and Recommended Values for the Integrated Trace File
Settings
Setting Default value
Recommended
value
Integrated trace file size 256 (KB) 4096 (KB)
Number of integrated trace files 4 8
Buffer size per
monitoring
interval
Monitoring cycle 10 (seconds) 5 (seconds)
Buffer size per
monitoring interval
64 (KB) 256 (KB)
Number of
messages to be
output per
monitoring
interval
Monitoring cycle 0 (seconds) 0 (seconds)
Number of messages
to be output
0 0
If Hitachi Network Objectplaza Trace Library (HNTRLib2) is already installed,
the existing settings will be inherited. If you change these settings, keep in
mind that programs other than HDLM also use them.
Notes on Using the Hitachi Network Objectplaza Trace Library
Note the following when using Hitachi Network Objectplaza trace library:
If HNTRLib has already been installed when you install HDLM, the settings
in the trace library will not be inherited by HNTRLib2. HDLM uses the
HNTRLib2 default settings.
If HNTRLib2 has already been installed on a host when you install HDLM,
the settings in the trace library will be inherited.
If a different Hitachi product is using HNTRLib2 when you attempt to
remove HDLM, HNTRLib2 will not be removed.
Displaying the Hitachi Network Objectplaza Trace Library setup
menu
To display the Hitachi Network Objectplaza Trace Library setup menu:
1. Log on as a root user.
2. Execute the following command:
3-88
Creating an HDLM Environment
Hitachi Dynamic Link Manager (for AIX) User Guide