Hitachi Dynamic Link Manager Software Users Guide for VMWare

collected-information-is-output] [-eventlogtime yyyy/mm/dd | -
eventlogsize {all | maximum-file-length}] | -h}
Parameters
host-name
Specify the host name for which to collect error information.
user-name
Specify the user name used to log in to the host.
password
Specify the password used to log in to the host.
folder-to-which-collected-information-is-output
Specify the output folder for the information that is to be collected by the
DLMgetras utility. The output-destination folders shown in Table 7-1 List
of Error Information Collected by the DLMgetras Utility for Collecting
Error Information on page 7-4 are created in a folder of your choosing,
and the information is then stored in the output-destination folders.
-eventlogtime yyyy/mm/dd
The utility obtains logs from each application, system, and security event
log. The logs obtained are those output after 00:00 on the date
yyyy/mm/dd. Specify the date in the yyyy/mm/dd format.
-eventlogsize {all | maximum-file-length}
all
Logs from all applications, systems, and security event logs are
obtained.
maximum-file-length
The utility obtains logs from each application, system, and security
event log. The logs are obtained, starting from the most recent log,
until the log size reaches maximum-file-length. Specify the log size in
MB. The specifiable value ranges from 1 to 4096.
-h
Displays the format of the DLMgetras utility.
Note:
¢
You cannot specify the -eventlogsize {all | maximum-file-
length} parameter together with the -eventlogtime yyyy/mm/dd
parameter.
¢
If neither the -eventlogsize {all | maximum-file-length}
parameter nor the -eventlogtime yyyy/mm/dd parameter are
specified, the utility's default is to obtain a maximum of 8 MB of event
log data.
¢
If the specified folder to which collected information is output already
exists, an overwrite confirmation message is displayed. Responding
Utility Reference
7-3
Hitachi Dynamic Link Manager (for VMware®) User Guide