HP XP7 Continuous Access Synchronous for Mainframe Systems User Guide (TK911-96003)

DescriptionError code
(SSB2)
The S-VOL is protected by the Volume Retention.C32D
A request for a Add Pair operation was rejected because the specified secondary system is an unsupported
product.
C32E
The number of P-VOL cylinders is not the same or smaller than the number of S-VOL cylinders.)C32F
P-VOL and S-VOL capacities are not the same.C330
S-VOL cache is unavailable.C332
S-VOL DFW is disabled.C333
The S-VOL is the Cnt Ac-S Z P-VOL.C335
The S-VOL includes PIN data.C336
The S-VOL is in reserve status.C337
Copy pair cannot be created because of the either of the following reasons.C338
The S-VOL is in the intervention-required condition, protected, or unusable status.
The S-VOL is the S-VOL or Reserved volume of Business Copy, Reserved volume of Auto LUN, or the
volume of Cnt Ac-J Z pair.
The S-VOL is not available.C339
A request for an Add Pair operation was rejected because the secondary system is a not supported by Cnt
Ac-S Z.
C33A
The corresponding volume cannot be specified as an S-VOL because the volume is used as another pair’s
S-VOL.
C33B
A request for an Add Pair operation was rejected because the specified S-VOL was not mounted.C33C
The pair cannot be created because the S-VOL is not implemented or is blocked (DEV NOT READY status).C33E
The corresponding volume cannot be specified as an S-VOL because the volume is already specified as a
Cnt Ac-S Z pair volume.
C33F
The P-VOL is not accessible.C35C
There are fewer paths than the required minimum following a path failure or because an invalid path was
specified.
C370
The process that is performed after the copying process of Auto LUN in the S-VOL is in progress. Retry the
operation several minutes later.
C371
The process that is performed after the copying process of Auto LUN in the P-VOL is in progress. Retry the
operation several minutes later.
C372
A request for an Add Pair operation was rejected because the specified S-VOL is a Business Copy Reserved
volume.
C373
A request for an Add Pair operation was rejected because the specified P-VOL is a Business Copy Reserved
volume.
C374
The add pair operation is rejected because the number of active paths is less than the dedicated number of
minimum paths.
C378
There are fewer paths than the required minimum following a path failure or because an invalid path was
specified.
C379
An internal error occurred.C37A
The S-VOL is not available.C37B
The storage system level cache is not valid in the RCU.C37C
Troubleshooting using RAID Manager 109