HP XP7 Continuous Access Synchronous for Mainframe Systems User Guide (TK911-96003)

DescriptionError code
(SSB2)
The request for an Add Pair operation was rejected because the specified S-VOL was a Cnt Ac-J Z S-VOL
or journal volume.
CBED
The pair was not created because the specified P-VOL is part of a Cnt Ac-J Z pair for delta resync.CBEE
The pair operation failed because of one of the following reasons:CBFA
A CHA in the RCU for connecting Mainframe is not installed.
All CHAs in the RCU for connecting Mainframe is blocked.
The pair cannot be created because the consistency group number is not within the supported range.CBFC
SSB2=B992 error codes when SSB1 = B901 or B90A
DescriptionError Code
(SSB2)
Error Code
(SSB1)
Pair cannot be created because DKC type dose not support Cnt Ac-S Z Asynchronous.B992B901
Consistency group information cannot be retrieved because Cnt Ac-S Z or Cnt Ac-J Z
is not installed.
B992B90A
Service Information Messages (SIMs)
The XP7 generates a service information message (SIM) to notify users of a possible service
requirement for the storage system. The SVP reports all SIMs related to Continuous Access
Synchronous Z operations. The SIMs reported to the zSeries and S/390 host are logged in the
SYS1.LOGREC dataset of the host operating system.
SIMs are classified according to the following severities: service, moderate, serious, or acute.
The following figure shows a typical 32 byte SIM from the XP7. SIMs display on the host console
by reference code (RC) and severity. The six digit RC (composed of bytes 22, 23, and 13) identifies
the possible error and determines the severity. The SIM type (byte 28) indicates the component
that experienced the error. When byte 22 = 21, the SIM is a control unit SIM. When byte 22 =
Dx, the SIM is a device SIM. When byte 22 = (D8 DC), the pair is Continuous Access Synchronous
Z. The SIM reference code DBFx indicates that the P-VOL status does not match with the S-VOL
status, or the capacity of the paired volume in the RCU exceeds the licensed capacity of Volume
Retention.
For further information about SNMP operations and SIMs, see the HP XP7 Remote Web Console
User Guide, or contact your HP account team.
TPC-R troubleshooting
The following failure conditions and recovery solutions are provided for Basic HyperSwap function
using TPC-R.
Service Information Messages (SIMs) 113