HP XP7 Continuous Access Synchronous for Mainframe Systems User Guide (TK911-96003)

To enable data migration from existing storage to the EAV (3390-A), you can combine a non-EAV
(3390-X) as the P-VOL and an EAV (3390-A) as the S-VOL. However, a reversed combination in
which EAV (3390-A) is the P-VOL and non-EAV (3390-X) is the S-VOL is not supported.
NOTE: You can use data migration from an earlier storage model P-VOL to an EAV S-VOL. When
you do this, note that the following two field values for the S-VOL in the Remote Web Console
Detailed Information dialog box:
The emulation type is shown as ......
If the S-VOL’s number of cylinders is greater than 65,535, it is still indicated as 65,535
RAID Manager support for Continuous Access Synchronous Z operations
You can run pair operations and path operations using RAID Manager for Continuous Access
Synchronous Z pairs and Continuous Access Synchronous pairs on a UNIX or PC server connected
to the P9500s.
A LUN on the P9500 target port must be defined and a command device created for RAID Manager
prior to using the interface. You can define the LUN to a logical volume for an open server that is
connected to a UNIX or PC server. For more information about command device settings, see the
HP XP7 RAID Manager User Guide.
Supported operations and options
The following table shows the Remote Web Console operations and options that are supported,
and not supported, by RAID Manager.
RAID Manager supportOptionRWC operation typeCategory
Yes(no option)Create PairsPair
Operation
YesInitial Copy
YesCopy Pace
1
No (fixed to 32)Priority
No (fixed to Auto)Difference Management
No (fixed to S-VOL)
2
CFW Data
No (fixed to DFW not required)DFW to S-VOL
No (fixed to Disable)
3
Time Stamp
Yes(no option)Split Pairs
No (fixed to Disable)SSB[F/M-FB]
No (fixed to S-VOL)Split Kind
Yes(no option)Resync Pairs
YesP-VOL Fence Level
YesCopy Pace
1
No (fixed to 32)Priority
No fixed to S-VOL
2
CFW Data (not in RWC for this
operation)
No (fixed to Disable)
3
,
4
Time Stamp
Yes(no option)Delete Pairs
No (fixed to Normal)
3, 4
Deleting Mode
26 Requirements and specifications