HP XP7 Continuous Access Synchronous for Mainframe Systems User Guide (TK911-96003)

2. To check path and port information, fromthe Storage Systems tree, click Replication > Remote
Connections > Connections (To).
Check connections under View Port Condition.
Check Status and other details in the Connections (To) tab.
Remote path status definitions
The following table provides remote path status descriptions.
DefinitionStatus
This path has been successfully established and can be used for Continuous Access
Synchronous Z remote copy activities.
Normal
The link initialization procedure with the secondary system has failed, because the physical
path connection between either the primary and secondary system, or between the primary
system and the host, was missing.
Initialization Failed
A timeout error has occurred between the primary and secondary system.Communication Timeout
The remote path link function has been rejected by the secondary system. All remote path
resources in the secondary system might be used for other connections.
Path Rejected
The serial number of the control unit that is connected to this remote path does not match
the serial number specified by the Add Remote Connection window.
Serial Number Mismatch
The specified port does not have the initiator attribute.Invalid Port Mode
There are three possible causes:RCU Port Number
Mismatch
The specified port in the secondary system is physically disconnected from the primary
system.
The port is not configured as an RCU target port.
The specified port number is not available.
Monitoring and maintaining remote connections and paths 85