HP XP7 Owner Guide (H6F56-96006)

Figure 20 XP7 system control panel
DescriptionItemDescriptionItem
ALARM - Red LED2MESSAGE - Amber LED1
Indicates DC under voltage of any DKC part, DC
over current, abnormally high temperature, or that
an unrecoverable failure occurred.
ON: indicates that a SIM (Message) was
generated from either of the clusters. Applied
to both storage clusters.
Blinking: Indicates that a SVP failure has
occurred.
PS ON - Green LED4READY - Green LED Indicates that input/output
operation on the channel interface is enabled.
3
Indicates that the system is powered on, that the
POST is complete, and that the system has booted
up and is ready for use.
REMOTE MAINTENANCE PROCESSING - Amber
LED
6BS ON - Amber LED
Indicates that the Sub Power supply is on. (CL
1 or CL 2). This LED remains on even when
5
Indicates that the system is being remotely
maintained.the DKC is powered off. It will turn off only
if the base power is removed (e.g. PDUs shut
off, wall power turned off, power outage,
etc.)
PS SW ENABLE - switch8REMOTE MAINTENANCE ENABLE/DISABLE -
switch
7
Used to enable the PS ON/PS OFF switch. This
switch must be moved to the enable position before
the PS ON/OFF switch will function.
When ON, permits remote maintenance.
--PS ON/PS OFF - switch9
Turns the system power on or off. Requires
that the PS SW ENABLE switch first be held
to the Enable position before use.
DKC Panel Jumpers
The disk control panel jumpers are used to control operations of the disk array.
System control panel 63