l The size of an application is often over 10 MB. Even if the baud rate is set to 115200 bps, it
usually takes about 30 minutes to upgrade the application through the serial interface. Therefore,
you are recommended to upgrade applications through an Ethernet interface.
l If you want the SecBlade card to use the downloaded file, you need to specify the file for the next
boot. For related information, refer to Specifying Files on page 15.
Upgrading the BootWare Program
Select 7 on the main menu (refer to Main Menu on page 19) to enter the BootWare operation
submenu, where you can perform all operations related to the BootWare program. For details about
the BootWare operation submenu, refer to BootWare Operation Submenu on page 24.
The following example shows how to upgrade the entire BootWare program:
Step1 Modify the baud rate of the serial interface to improve the upgrade speed (for details, refer to
Modifying Serial Interface Parameters on page 26) and then select 3 on the BootWare operation
submenu. The following information is displayed:
===========<BOOTWARE OPERATION SERIAL SUB-MENU>==============
| <1> Update Full BootWare |
| <2> Update Extended BootWare |
| <3> Update Basic BootWare |
| <4> Modify Serial Interface Parameter |
| <0> Exit To Main Menu |
=============================================================
Enter your choice(0-4):
Step2 Select 1. The following information is displayed:
Waiting ...CCCCCCCCCCCCCCCCCCCCCCCCC...
Step3 Select Transfer > Send file in the HyperTerminal window. The following dialog box appears: