2) Configure Ethernet interface parameters on the BootWare menu.
Select 3 on the main menu to enter the Ethernet submenu, where you can select 5 to enter the
Ethernet parameter setting interface to configure the Ethernet interface parameters.
==================<ETHERNET PARAMETER SET>===================
Note: '.' = Clear field.
'-' = Go to previous field.
Ctrl+D = Quit.
=============================================================
Protocol (FTP or TFTP):tftp
Load File Name :main.bin
:main.bin
Target File Name :main.bin
:main.bin
Server IP Address :192.168.80.200
Local IP Address :192.168.80.10
Gateway IP Address :
FTP User Name :
FTP User Password :
Table 16 Description of display information about Ethernet interface parameter configuration
Field Description
'.' = Clear field To clear the current field, input a (.) and then press Enter.
'-' = Go to previous field
To go to the previous field, input a hyphen (-) and then
press Enter.
Ctrl+D = Quit
The shortcut key combination for quitting the Ethernet
parameter setting interface is Ctrl+D.
Protocol (FTP or TFTP) Select TFTP or FTP to upgrade applications.
Load File Name
Select the file to be downloaded.
Set the path where the file is stored on the TFTP server.
l The first main.bin is the file name automatically
remembered by the system at the last update; the second
main.bin is the source file name set by the user.
l An application file name including the extension such as .bin,
cannot exceed 50 characters.