HP Switch Services Modules - H3C SecBladeII-CMW520-F3171P11 Release Notes

H3C SecBladeII-CMW520-F3171P11
Release Notes
Hangzhou H3C Technologies Co., Ltd.
14
List of Resolved Problems
Resolved Problems in F3171P11
Problem 1
First found-in version: SECBLADEII-CMW520-F3171P07
Condition: The device has been running for over 30 weeks.
Description: There is a drift of several minutes between the time recorded in the userlog
and the exact system time.
Resolved Problems in F3171P07
Problem 1
First found-in version: F3170
Condition: Query the system log by Web UI.
Description: If the total item of system log is over 65535, the Web page can not be
opened successfully.
Problem 2
First found-in version: F3170
Condition: Active/Standby Failover.
Description: With Active/Standby failover, when the active unit fails, the standby unit
changes to the active state. But the traffic can't pass through. When entering
command eset session in this unit, the traffic can get through again.
Resolved Problems in F3171P03
Problem 1
First found-in version: F3170
Condition: When the device memory occupancy rate high, equipment processing
software interlocking may lead to abnormal.
Description: None.
Problem 2
First found-in version: F3170
Condition: Modify address group object failed, and then click the navigation tree
inter-domain strategy, equipment abnormal restart.