HP Switch Services Modules - H3C SecBladeII-CMW520-F3171P11 Release Notes

H3C SecBladeII-CMW520-F3171P11
Release Notes
Hangzhou H3C Technologies Co., Ltd.
15
Description: None.
Problem 3
First found-in version: F3170
Condition: Through the firewall FTP login, the firewall network configuration of Nat
Server cases, the client through the private network address directly login, data
channel establishing matching Nat Server leads to the data passage establishment
failure.
Description: None.
Problem 4
First found-in version: F3170
Condition: FIN message two times from different direction after the firewall, a direction
FIN message will be dropped by firewall.
Description: None.
Problem 5
First found-in version: F3170
Condition: Import the IP address and the address set of resources lead to abnormal
restart.
Description: None.
Problem 6
First found-in version: F3170
Condition: The SNMP Test connection equipment, the use of SHA-3DES will lead to
abnormal.
Description: None.
Problem 7
First found-in version: F3170
Condition: When the session memory rises to a peak, even if the session number is small,
the memory is still not released.
Description: None.
Resolved Problems in F3170
First release.