HP Switch Services Modules - H3C SecBladeII-CMW520-F3171P11 Release Notes

H3C SecBladeII-CMW520-F3171P11
Release Notes
Hangzhou H3C Technologies Co., Ltd.
26
Table 10 Default login information
Login information Default setting
Username admin
Password admin
IP address of GigabitEthernet 0/0 on the firewall
card for S5800 and SR6600
192.168.0.1/24
IP address of GigabitEthernet 0/1on the firewall
card for other network devices
192.168.0.1/24
To upgrade the system software from the Web:
1. Use an Ethernet cable to connect the firewall card to the PC.
2. Assign an IP address on subnet 192.168.0.0/24 (except 192.168.0.1) to the PC.
In this example, assign 192.168.0.2 to the PC.
3. Run the IE, and enter 192.168.0.1 in the address bar.
The Web login page appears.
4. Type the default username and password, and click Login.
5. Select Device Management > Software Upgrade from the navigation tree.
Figure 2 Upgrading the software
6. Specify the software upgrading configuration items as described in Table 11 .
Table 11 Configuration items
Item Description
File
Click Browse to set the path to the system software image
file.
The file name must end with .bin.