HP Switch Services Modules - H3C SecBladeII-CMW520-F3171P11 Release Notes

H3C SecBladeII-CMW520-F3171P11
Release Notes
Hangzhou H3C Technologies Co., Ltd.
36
Figure 8 File transfer progress
13. When the Serial submenu appears after the file transfer is complete, enter 0 at the
prompt to return to the BootWare menu.
Download successfully!
19790016 bytes downloaded!
Input the File Name:main.bin
Updating File cfa0:/main.bin..............................................
.....................................................Done!
===========================<Enter Serial SubMenu>===========================
|Note:the operating device is cfa0 |
|<1> Download Application Program To SDRAM And Run |
|<2> Update Main Application File |
|<3> Update Backup Application File |
|<4> Update Secure Application File |
|<5> Modify Serial Interface Parameter |
|<0> Exit To Main Menu |
============================================================================
Enter your choice(0-5):
14. Enter 0 to return to the BootWare menu, and enter 1 in the BootWare menu to boot the
system.
15. If you are using a download rate other than 9600 bps, change the baud rate of the