TMS zl Module Release Notes ST.1.0.090213

17
Known Issues
Release ST.1.0.090213
PR_0000015477 — When adding and removing VLANs via the CLI, additional log messages
are created that are not created when using the Web browser interface to add and remove
VLANs.
PR_0000015522 — There is a difference in how the timezone information is displayed in
the TMS zl Module as compared to the switch. The TMS zl Module follows the POSIX standard
for displaying the time, for example, 'GMT+6' is displayed to indicate the timezone. However,
the switch uses a negative number to set the timezone. The time is correctly displayed in
both cases, but the process to set the timezone may cause some confusion.
PR_0000016231 — Some log entries for warning logs and information logs have messages
that are truncated in the log viewer. The most log messages are not truncated and those that
are contain enough information that a user can tell what they are about. However, the
messages have more information in them than can be displayed.
PR_0000016539 — When using the TMS zl Module CLI, the radius-server help command
gives options that are not available.
PR_0000016546 — A TMS zl Module module that incorrectly has duplicate IP addresses
for its VLANs may cause the TMS zl Module SNMP daemon to restart, which may hide the
actual problem from a user. While it is incorrect to have duplicate IP addresses, this may
occur, and the SNMP daemon restart may send the administrator down the wrong
troubleshooting path.
PR_0000016812 — When a user incorrectly logs into a TMS zl Module resulting in an
authentication failure, if the TMS zl Module is setup to send traps, it will send an
authentication failure trap. However, the trap does not contain the user's IP address or the
username.
PR_0000016892 — When the local log contains more than 10,000 entries, the oldest entries
(after the 1,000th entry) are displayed in a wrong position.
Steps to reproduce:
1. Get more than 10,000 entries in the local log
2. Either export the local log or, in the Web browser interface, set the number of entries per
page to 500 and go to page 6.
PR_0000018145 — In the Web browser interface, if a VLAN is added with an invalid IP
address in the range 224.0.0.0 - 254.255.255.255, an error is returned stating:
VLAN could
not be added. Failed to add VLAN IP address
, but the VLAN is actually added, but
not associated to any zone. In the CLI, the error message only states:
Error: Failed to
set VLAN IP address:
PR_0000018197 — The Web browser interface Help incorrectly states the number of VLAN
associations supported as 21. It should be 19.