TMS zl Module Release Notes ST.1.0.090213

23
Known Issues
Release ST.1.0.090213
rate or count drops, the state is transferred correctly. However, should a failover from the
Master to the Participant occur at the time when TCP state information cannot be sent, there
will be an additional failover delay as applications re-establish their TCP state with the
Participant (now the Master after the failover).
Monitor Mode Only
PR_0000005928 — When in Monitor Mode, a scan of the open ports will reveal TCP port
616 and TCP port 9999 as being open. The only way to block these ports is to setup a firewall
access policy to restrict them.
PR_0000007533 — If the TMS zl Module is in monitor mode, the IDS logs incorrectly show
zones Internal and Zone6 in the logs for data and management. These zone references are not
correct and should be ignored.
PR_0000011929 — When in monitor mode and using the TMS zl Module CLI, if you add
an management IP address, the CIDR format of IP-Address/mask is not accepted and you
must enter the IP address and Subnet Mask as separate values.
PR_0000014582 — In monitor mode, the CLI command ips help does not reflect the
commands that are actually available in monitor mode as opposed to routing mode.
PR_0000015755 — In monitor mode, the management VLAN can be deleted from the
switch. In routing Mode, the user is prevented from making this change on the switch.
Example:
Preconditions: monitor mode, management VLAN and management IP address have been set. In
this example, the management VLAN is 30.
Delete the management VLAN from the switch CLI.
ProCurve Switch (tms-module-D:config)# no vlan 30
An error message should be displayed preventing the deletion of the VLAN due to its use by the
TMS zl Module. A user is not prevented from performing this action and the VLAN is deleted. As
a result, the Web browser interface of the TMS zl Module can't be accessed because the
management VLAN has been deleted
PR_0000017758 — In monitor mode, when IPS full inspection is turned on and the FTP
ALG is turned off, sending an FTP copy of the startup configuration to the network fails with
a broken pipe error.