Known Issues
Release ST.1.1.100226
PR_50252 — Performance Related HA + 256 VLAN configured issue - scheduled to be
addressed in May-June 2010 release.
PR_50394 — In the Web browser interface in the Settings->Logging->View Log page, when
positioning the mouse cursor over a log, the text false is displayed at the bottom of the page.
This behavior appears when using Internet Explorer 6.
PR_50465 — Performance Related - excessive logging during times of high packet
throughput - scheduled to be addressed in May-June 2010 release.
PR_51091 — IP Addresses may get translated for ICMP traffic when they shouldn't be. Steps:
1. Add access service group (e.g., basic (ftp, telnet, ssh, http)
2. Add access policies (e.g., from Zone1 to External; basic; any ;any and Zone1 to External;
ICMP, any; any)
3. Add a Source NAT policy (e.g., NAT from Zone1 ->External Services FTP, HTTP,SSH; Source
Any, dst 10.10.100.1-10-10.100.20 NAT value 10.10.100.111)
4. Open FTP server or any of the basic services
5. Verify IP address gets translated on the destination zone
6. Send ICMP traffic
7. Verify IP address gets translated on the destination zone when it should not be.
PR_51154 — Under high load with 100% CPU utilization, rebooting the TMS zl Module
causes the TMS zl Module to temporarily hang during the boot process. The TMS zl Module
will recover when the load decreases and frees up the CPU.
PR_51303 — If a RIP interface is disabled, deleted, then added back with the same IP
configuration, re-enabled again, it will not send out RIP updates any more. Workaround:
disable the RIP interface again and then re-enable it.
PR_51502 — In the CLI, the command capture file any ether ? does not list choices available.
PR_52023 — Performance Related IPS issue - Scheduled to be addressed in May-June 2010
release - Should not affect users with < 75% CPU utilization.
PR_52143 — In the TMS zl Module CLI, the command 'ping' would ignore the repetitions
option if the data-size parameter was specified before it. Workaround: Specify the repetitions
option before the data-size option.
PR_52174 — A Communications error dialog displays when attempting to change the
following settings in the TMS zl Module with PCM Device Manager:
sysName
sysContact
sysLocation