Wireless/Redundant Edge Services xl Module Management and Configuration Guide WS.02.xx and greater

Table Of Contents
2-65
Configuring the ProCurve Wireless Edge Services xl Module
Radio Port Adoption
Replace <port number> with the number of the port to which the RP
connects. The CLI displays the RP’s boot code in the System Description
field as the HwBoot Version. For example, the bootloader code for an RP
that was last adopted by a version 01.XX module is 0.4.
If the RP has the old boot code (0.4), you must have a Wireless Edge
Services xl Module that runs version 02.XX software pre-adopt the RP at
Layer 2. As part of the adoption process, this module will automatically
update the RP’s bootloader code, as you can check in the Device Informa-
tion > Radio Adoption Statistics screen (see Figure 2-35).
The code automatically updates.
Figure 2-35. Checking an RP’s Bootloader Code Through the Module’s Web
Browser Interface
With the new bootloader code, the RP can complete Layer 3 adoption. You
can now install the RP in its final location, and as long as you set up other
requirements described below, the RP will be adopted at Layer 3.
2. On your DHCP server, you can create a fixed configuration specifically
for the RP, or you can add option 189 to a pool already configured for other
stations.
Boot code