HP Remote Graphics Software 5.4.0 User Guide

This property was added with RGS 5.4.0 and allows the user to disable a visual notification when the
network has timed out. When the Rgreceiver.Network.Timeout.IsGuiEnabled property is set to 1 the
network timeout is shown. When the Rgreceiver.Network.Timeout.IsGuiEnabled property is set to 0 the
visual network timeout notification is not shown. See
Receiver network timeouts on page 128 for more
details.
Rgreceiver.Network.Timeout.Warning=int 2000
Rgreceiver.Network.Timeout.Warning.IsMutable=int 1
The timeout in milliseconds used to detect and notify the user of a network disruption. The default value
is 2,000 milliseconds (2 seconds).
Rgreceiver.Network.Timeout.Error=int 30000
Rgreceiver.Network.Timeout.Error.IsMutable=int 1
The timeout in milliseconds used to detect and disconnect an inactive connection. The default value is
30,000 milliseconds (30 seconds).
Rgreceiver.Network.Timeout.Dialog=int 15000
Rgreceiver.Network.Timeout.Dialog.IsMutable=bool 1
This property specifies the timeout in milliseconds used to display, and wait on responses from, input
dialogs, such as the authorization dialog and the PAM authentication dialog. The default value is
15,000 milliseconds (15 seconds).
8.5.9 Receiver hotkey properties
Rgreceiver.Hotkeys.IsMutable=bool 1
If set to 1, all Hotkey settings in the Receiver Control Panel can be changed by the user. If set to 0,
none of the hotkey settings can be changed by the user. This property can be used to permanently
enable or disable hotkey settings before the RGS Receiver is started. The default value is 1—hotkeys
can be changed by the user.
Rgreceiver.Hotkeys.IsSetupModeEnabled=bool (1)
This property was added with RGS 5.4.0 and allows the user to completely disable all hotkeys. When
the Rgreceiver.Hotkeys.IsSetupModeEnabled property is set to 1 the hotkeys will work as normal. When
the Rgreceiver.Hotkeys.IsSetupModeEnabled property is set to 0 all hotkeys are disabled. In other
words pressing the hotkey sequence will not do anything. See
Hotkeys on page 135 for more details.
Rgreceiver.Hotkeys.SetupModeSequence=string “Shift Down, Space Down, Space up
Rgreceiver.Hotkeys.SetupModeSequence.IsMutable=bool 1
Defines the Setup Mode hotkey sequence. The sequence may only consist of Ctrl, Alt, Shift and Space
keys. The sequence must also start with either a Ctrl, Alt or Shift key. The first key must also be held
down through the entire hotkey sequence. The default value is "Shift Down, Space Down, Space Up".
Rgreceiver.Hotkeys.IsSendCtrlAltEndAsCtrlAltDeleteEnabled=bool 1
Rgreceiver.Hotkeys.IsSendCtrlAltEndAsCtrlAltDeleteEnabled.IsMutable=bool 1
When enabled a Ctrl-Alt-End key sequence in the Remote Display Window is sent to the Remote
Computer as a Ctrl-Alt-Del key sequence. The default value is 1—send a Ctrl-Alt-Del when the user
enters Ctrl-Alt-End.
168 Chapter 8 RGS properties ENWW