HP StorageWorks Reference Information Storage System V1.4 Administrator Guide (T3559-96027, March 2006)

Displaying doma
in-afliated smart cells
1. In the View Cell Space view, nd the smart cell's domain.
2. Find the smart cell's sm art c ell group identication number.
3. Click the smart
cell's name. The Agent view appears.
Displaying unafliated smart cells
Unafliated smart cells are “free and contain no data.
To display unafliated smar t cells:
1. Scroll to the bottom of the View Cell Space view.
2. To display the Agent view, nd the smar t cell's smar t cell group identication number and click
the smart cell's name.
Determining
if smart cells are primary or secondary cells
1. In the View Cell Space view, nd the smart cell's domain.
2. Find the smart cell's smart cell group identication number. Primary and secondar y cells are
designated by the rst letter in the smart cell group identication number:
•P(primary)
•S(secondary)
Determining if smart cells are used for replication
1. In the View Cell Space view, nd the smart cell's domain.
2. Find the smart cell's smart cell group identication number. Replicas are designated by the rst letter
in the smart cell group identication numb er:
R1 (primary replica)
R2 (secondary replica)
Restori
ng data on failed smart cells
To resto
redataonafailedsmartcell,youmusthaveatleastonefreesmartcell.Ifonlyonesmartcellin
agroupfailed,cloneasmartcellinstead(see"Smartcell Cloning" on page 52).
To restore a smart cell, the following must occur:
Its domain has DataBackupEnabled=true set in Domain.jcml.
Its gro
up was assigned in this system at one time.
It is marked as missing in the ViewCellState table or no record exists in the ViewCellState table.
NOTE:
Rebuilding the index on the smart cell takes a signicant amount of time depending on the amount
of data being restored.
If both smart cells in a g roup failed, perform the following:
1. In the View Cell Space view, scroll to the Unafliated SmartCells area, and verify that at le ast one
free smart cell exists.
2. Locate the p rimary controller:
a. Under MetaServer, click the link to the primary or m ain controller (metaserver). The Agent
view appears.
Reference Information Storage System