HP StorageWorks Virtualization Services Manager v2 server user guide (5697-0137, September 2009)

2 Operations
Power up the server
To power up the server, press the Power On/Standby button.
Power down the server
WARNING!
To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power
cord to remove power from the server. The front panel Power On/Standby button does not completely
shut off system power. Portions of the power supply and some internal circuitry remain active until
AC power is removed.
IMPORTANT:
If installing a hot-plug device, it is not necessary to power down the server.
1. Back up the server data.
2. Shut down the operating system as directed by the operating system documentation.
3. If the server is installed in a rack, press the UID LED button on the front panel. Blue LEDs illuminate
on the front and rear panels of the server.
4. Press the Power On/Standby button to place the server in standby mode. When the server
activates standby power mode, the system power LED changes to amber.
5. If the server is installed in a rack, locate the server by identifying the illuminated rear UID LED
button.
6. Disconnect the power cords.
The system is now without power.
Extend the server from the rack
NOTE:
If the optional cable management arm option is installed, you can extend the server without powering
down the server or disconnecting peripheral cables and power cords. These steps are only necessary
with the standard cable management solution.
HP StorageWorks Virtualization Services Manager v2 server user guide 17