HP StorageWorks SAN Virtualization Services Platform SMI-S User Guide (5697-0209, April 2010)

Class keys/properties
CommentsDescriptionProperty name
An ID that uniquely defines the one in-
stance of this class within the vendor
namespace.
" < domain>";"+Controller-
MaskingCapabilities"
InstanceID
A user friendly name for the instance.
StorageMaskingCapabilit-
ies"
ElementName
Mandatory
1 ( Other )
2 ( Port WWN )
3 ( Node WWN )
4 ( Host Name )
5 ( iSCSI Name
Set this to the array: { 2
("Port WWN") }
ValidHardwareIdTypes
Mandatory
2 ( One Port per Snapshot )
3 ( Multiple Ports per Snapshot )
4 ( All Ports share the same Snap-
shot )
4 ("All Ports Share the
Same Snapshot")
PortsPerSnapshot
Indicates this storage system allows the
client to specify the DeviceNumbers
parameter when calling ControllerCon-
figurationService. ExposePaths().
TrueClientSelectableDeviceNumbers
The storage system does not limit the
number of hardwareIDs in a snapshot
(protocol storage system)
FalseOneHardwareIDPerSnapshot
When set to false, the storage system
does not allow a client to create a
Privilege instance with PrivilegeGranted
set to FALSE.
FalsePrivilegeDeniedSupported
When set to false, different ProtocolCon-
tollers attached to a LogicalPort can
expose the same unit numbers.
FalseUniqueUnitNumbersPerPort
The maximum number of ProtocolCon-
trollerForUnit associations that can be
associated with a single LogicalDevice.
0 means unlimited mappings are al-
lowed.
0MaximumMapCount
The storage system does not allow a
client to create a configuration where
an SPC has no LogicalDevices associ-
ated via CIM_ProtocolControllerForUnit
associations
FalseSPCAllowsNoLUs
SAN Virtualization Services Platform SMI-S User Guide 107