HP StorageWorks SAN Virtualization Services Platform SMI-S User Guide (5697-0209, April 2010)

CommentsDescriptionProperty name
The storage system does not allow a
client to create a configuration where
an SPC has no target SCSIProtocolEnd-
points associated via CIM_SAPAvail-
ableForELement associations.
FalseSPCAllowsNoTargets
The instrumentation does not allow a
client to create a configuration where
a ProtocolController has no Storage-
HardwareIDs associated
FalseSPCAllowsNoInitiators
Set to true if it the instrumentation sup-
ports 'default snapshot' protocol control-
lers that exposes logical units to all ini-
tiators.
FalseSPCSupportsDefaultSnapshots
Indicates the this implementation sup-
ports VSM hosts.
TrueProtocolControllerSupportsCollections
Indicates that this implementation sup-
ports ExposePaths and HidePaths
methods.
TrueExposePathSupported
Class associations
PropertyToAssociation name
Capabilities
HPSVSP_StorageAppliance : CIM_Com-
puterSystem
HPSVSP_ControllerMasking Capabilities :
CIM_ElementCapabilities
HPSVSP_ControllerForEndpoint : CIM_SAPAvailableForElement
Class introduction
This association represents the target ports used by a SCSIProtocolController in masking. In VSM
terms, assigning permissions to a UDH requires using ports on a DPM group, and hence, the
SCSIProtocolController will have associated front-end HBAs/ports.
Class keys/properties
CommentsDescriptionProperty name
Association reference
property.
A reference to a DPM
front-end HBA.
HPSVSP_DPMFrontSideSCSIProtocolEndpoint REF Avail-
ableSAP
Association reference
property.
A reference to the Proto-
colController.
HPSVSP_SCSIProtocolController REF ManagedElement
Masking and Mapping Profile108