HP StorageWorks SAN Virtualization Services Platform Data Path Module User Guide This guide provides information about accessing and using the graphical user interface (GUI) and the command line interface (CLI) of the HP StorageWorks SAN Virtualization Services Platform (SVSP) Data Path Module (DPM).
Legal and notice information © Copyright 2008-2010 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice.
Contents 1 Data Path Module management interface options ................................... 9 2 Using the command line interface ...................................................... 11 CLI overview ............................................................................................................................ Command quick reference by object ..................................................................................... Command syntax and command completion ............................
Enable ssh command ................................................................................................................ Enable syslog command ............................................................................................................ Enable telnet command ............................................................................................................. Enable user command .................................................................................................
Show images command ............................................................................................................ Show license command ............................................................................................................. Show log command .................................................................................................................. Show ntp command .......................................................................................................
Product warranties .................................................................................................................... 86 HP websites ............................................................................................................................. 86 Documentation feedback ........................................................................................................... 86 Glossary ........................................................................................
Figures 1 PuTTYtel Configuration screen ................................................................................... 14 2 PuTTYtel session login screen .................................................................................... 14 3 PuTTYtel console menu options .................................................................................. 15 4 HP Storage Services Platform screen ..........................................................................
Tables 1 Commands by object type ....................................................................................... 11 2 Built-in users and groups .......................................................................................... 16 3 DPM Management GUI functions .............................................................................. 73 4 Document conventions .............................................................................................
1 Data Path Module management interface options There are two ways to interface with the Data Path Module (DPM): • Over a serial connection using the DPM management command line interface (CLI) • Over an IP connection using the DPM management graphical user interface (GUI) Most activity with the DPM GUI occurs during initial configuration and debugging (when requested by HP Support). Therefore, under normal operation, the DPM GUI is seldom used.
Data Path Module management interface options
2 Using the command line interface This chapter describes the use of the HP StorageWorks SAN Virtualization Services Platform Data Path Module (DPM) command line interface (CLI). You can configure and manage the DPM with these common command sets that provide the same functions as the DPM GUI. CLI overview The DPM provides a command line user interface through serial, telnet, and ssh connections with serial being the preferred default.
Object type snmp date/timezone Command Page Enable user command 32 Show user command 65 Show users command 65 Create snmp command 19 Disable snmp command 25 Enable snmp command 30 Modify snmp command 40 Show snmp command 62 Modify date command 36 Modify timezone command 41 Show date command 51 Show fan command 55 Show fans command 56 Show group command 57 Show groups command 57 Show therm command 64 Show therms command 64 Show ps command 61 Show pss command 61 Show
This CLI provides command completion to minimize the typing needed to run commands. This feature enables you to press the completion key (the Tab key) to complete a partially typed command line. If the command line fragment is unambiguous, it is completed with the remainder of the command line. If there is more than one possible match for a command line fragment, continue pressing the Tab key to see each of the possible matches.
1. With a serial cable between the VSM server and the DPM, open a PuTTYtel session. Figure 1 PuTTYtel Configuration screen . 2. Ensure a speed of 9600 is used with a Serial connection type, and click Open. A login screen appears. Figure 2 PuTTYtel session login screen .
3. Log in to the DPM with the default login and password. NOTE: HP recommends that you change the default password. If you have not already done so, run the “Modify user command” on page 42 to change the password. login: admin password: password The following menu options are displayed (see Figure 3). Figure 3 PuTTYtel console menu options . 4. Enter commands from the command line to begin managing the DPM with the CLI commands.
“Modify eth command” on page 36, “Modify port command” on page 38, and “Modify ports command” on page 39 for more information. Table 2 summarizes the features of the built-in groups. Table 2 Built-in users and groups Built-in users Built-in groups Default password View system configuration and status Create/delete users and modify eths/ports/users/...
3 CLI commands Activate command Makes sure that the DPM is active (init 3 is up, and all SOAP modules are loaded). Syntax activate Add license command Adds a new license. Syntax add license [key] Keyword values [key] License key to be added. Notes Only users belonging to the Administrator group can add or delete licenses. See also “Delete license command” on page 20 “Show license command” on page 58 Add syslog command Adds a remote logging server.
Keyword values [host] Host name of the remote logging server. [port-number] IP port number to which the host connects. [socket-protocol] Socket protocol (either TCP or UDP, with default being TCP). Notes Only users belonging to the Administrator group can add or delete syslog servers. See also “Add syslog command” on page 21 “Disable syslog command” on page 26 “Enable syslog command” on page 31 “Show syslog command” on page 63 Clear command Clears the screen of text.
Create snmp command Creates an SNMP receiver. Syntax create snmp receiver [name] Keyword values [name] Name of the SNMP trap receiver. See also “Delete snmp command” on page 21 “Disable snmp command” on page 25 “Enable snmp command” on page 30 “Modify snmp command” on page 40 “Show snmp command” on page 62 Create user command Creates a new user in the specified group, or views user settings. The groups defined for the DPM are Administrator and Monitor.
“Disable user command” on page 26 “Enable user command” on page 32 “Show user command” on page 65 “Show users command” on page 65 Delete config command Removes a configuration that was saved by the save config command. Syntax delete config [configuration file] Keyword values [configuration file] Configuration file name. See also “Load config command” on page 34 “Save config command” on page 46 “Show configs command” on page 50 Delete license command Removes a license.
Delete snmp command Removes an SNMP receiver. Syntax delete snmp receiver [name] Keyword values [name] Name of SNMP trap receiver. See also “Create snmp command” on page 19 “Disable snmp command” on page 25 “Enable snmp command” on page 30 “Modify snmp command” on page 40 “Show snmp command” on page 62 Delete syslog command Removes a remote logging server. Syntax delete syslog server [host] Keyword values [host] Host name of the remote logging server.
Delete user command Removes the specified user from the list of administrators who can access the DPM. Syntax delete user [user name] Keyword values [user name] Name of the user that you are removing from the system. Notes Only users belonging to the Administrator group can add, delete, and disable/enable users, and the current user cannot be disabled or deleted.
See also “Enable eth command” on page 27 “Modify eth command” on page 36 “Set eth command” on page 47 “Show eth command” on page 54 “Show eths command” on page 55 Disable ftp command Disables use of the File Transfer Protocol (FTP) program to copy files onto the DPM. Syntax disable ftp See also “Enable ftp command” on page 28 “Show ftp command” on page 56 Disable http command Disables use of the http protocol and DPM network management interfaces.
Keyword values [permission] Either read, write, or all. See also “Enable insecure command” on page 28 “Show security command” on page 62 Disable ntp command Disables use of the ntp protocol on the DPM. Syntax disable ntp See also “Enable ntp command” on page 29 “Modify ntp command” on page 38 “Restart ntp command” on page 45 “Show ntp command” on page 59 Disable port command Disables the specified Fibre Channel port number so that it cannot send and receive Fibre Channel traffic.
“Show port command” on page 59 “Show ports command” on page 60 Disable secure command (obsolete) NOTE: This command is obsolete and has been removed from the current version of the CLI. Disables permissions on SSL-encrypted transmissions. Syntax disable secure [permission] Keyword values [permission] Either read, write, or all. See also “Enable secure command” on page 30 “Show security command” on page 62 Disable snmp command Disables the specified Simple Network Management Protocol component.
Disable ssh command Disables use of the secure shell (ssh) application to connect to the DPM CLI. Syntax disable ssh See also “Enable ssh command” on page 31 Disable syslog command Stops logging to the specified remote logging server. Returns to the local logging mode. Syntax disable syslog [host] Keyword values [host] Host name of the remote logging server.
Syntax disable user [user name] Keyword values [user name] Name of the user account that you are disabling. See also “Create user command” on page 19 “Delete user command” on page 22 “Enable user command” on page 32 “Modify user command” on page 42 “Show user command” on page 65 “Show users command” on page 65 Enable bootset command Set the active bootset. Syntax enable bootset [number] Keyword values [number] The number 1 or 2.
Keyword values [interface name] Name of the Ethernet interface that you are enabling: MGMT, GE1, GE2, or GE3. See also “Disable eth command” on page 22 “Modify eth command” on page 36 “Set eth command” on page 47 “Show eth command” on page 54 “Show eths command” on page 55 Enable ftp command Enables use of the File Transfer Protocol (FTP) program to copy files onto the DPM.
Syntax enable insecure [permission] Keyword values [permission] Either read, write, or all. See also “Disable insecure command” on page 23 “Show security command” on page 62 Enable ntp command Enables use of the ntp protocol on the DPM.
“Modify ports command” on page 39 “Modify ports command” on page 39 “Show port command” on page 59 “Show ports command” on page 60 Enable secure command (obsolete) NOTE: This command is obsolete and has been removed from the current version of the CLI. Enables permissions on SSL-encrypted transmissions. Syntax enable secure [permission] Keyword values [permission] Either read, write, or all.
“Modify snmp command” on page 40 “Show snmp command” on page 62 Enable ssh command Enables use of the secure shell (ssh) application to connect to the DPM CLI. Syntax enable ssh See also “Disable ssh command” on page 26 “Show ssh command” on page 63 Enable syslog command Begins logging to the specified remote logging server. The remote server must have been added with the add syslog command. Syntax enable syslog [host] Keyword values [host] Host name of the remote logging server.
Enable user command Enables the user account that was previously disabled using the Disable user command. Syntax enable user [user name] Keyword values [user name] Name of the user account that you are enabling. Notes Only users belonging to the Administrator group can add, delete, disable and enable users. The current user cannot be disabled or deleted.
[command]? help [object] Keyword values [partial command name] Part of a help command (enough of the command to uniquely identify it). [command] Entire command name. [object] Object of the command (for example, in the show snmp command, snmp is the object). Examples create? returns this help information: create snmp receiver create debug dump create user group re? returns this help information: remove -- Remove an object. rescan -- Rescan for new devices.
Install image command Installs an image onto a bootset. Syntax install image [image-name] Keyword values [image-name] Image to be installed. See also “Show image command” on page 58 “Remove image command” on page 43 Load config command Load a configuration generated by a save config command. Syntax load config [configuration] Keyword values [configuration] Configuration to be loaded.
“Save debug command” on page 46 “Show debug command” on page 51 “Watch debug command” on page 67 Load factory command Restore the factory defaults (original values for rank and WWNN). Syntax load factory defaults See also “Modify factory command” on page 37 “Show factory command” on page 55 Modify chassis command Allows the user to set values for the DPM's name, location, WWNN, maxframesize, and rank values.
Examples modify chassis location “Second floor lab, Main Street office” modify chassis maxframesize 1024 See also “Show chassis command” on page 49 Modify date command Sets the system date and time. Syntax modify date [MM/DD/YYYY hh:mm:ss] Keyword values [MM/DD/YYYY hh:mm:ss] MM/DD/YYYY is the month, day, and year for the system time (year must be 4–digits long). hh:mm:ss is the hours, minutes, and seconds for the system time.
IPv4, IPv6 address [IP address] IP address of the interface. gateway [gateway address] IP address of the network gateway. netmask [subnet mask] Mask bits for subnet routing. Notes If you are connected through the management port, modifying the MGMT Ethernet terminates any active network GUI and CLI sessions, requiring a re-login through the serial or MGMT port. If you are using the CLI on the serial console, the connection is not disrupted.
Modify ntp command Change the NTP server. Syntax modify ntp server [server-name] Keyword values [server-name] New server to be used to get the time. See also “Disable ntp command” on page 24 “Enable ntp command” on page 29 “Restart ntp command” on page 45 “Show ntp command” on page 59 Modify port command Changes the specified options—type, capability, speed—for the specified Fibre Channel port number.
type [port name] UNKNOWN, AUTO, FABRIC, LOOP FABRIC: the port functions only in conjunction with a single-attached device that is capable of fabric mode operation. The default is fabric mode, with the fabric yielding better throughput, and links recover more quickly. NOTE: Only the FABRIC port name is supported with the HP StorageWorks SAN Virtualization Services Platform. Notes You must restart the system for port capability or port speed changes to take effect.
FCP_TARGET: to enable the port to be used as a front-end (looks like a storage array port). FCP_INITIATOR: to initiate back-end traffic to disks (cannot receive storage). both: traffic can go both ways. speed [port speed] 1G, 2G, 4G, NEGOTIATE maxframesize [size (in bytes)] Smallest maximum frame size of any device on the SAN, usually 2048. Some systems require 1024, or even smaller. This number specifies the maximum frame size that the DPM can negotiate to exchange with other Fibre Channel devices.
network managers to change the community string so that outsiders cannot see information about the internal network. See also “Create snmp command” on page 19 “Delete snmp command” on page 21 “Disable snmp command” on page 25 “Enable snmp command” on page 30 “Restart snmp command” on page 45 “Show snmp command” on page 62 Modify therm command Sets the maximum or minimum temperature thresholds allowed for the thermometer specified.
Your time zone, for example, “EST,” “GMT,” “Japan,” and so on. Type modify timezone for a full list of possible values. Notes Once the time zone is set, the system automatically switches between Standard Time and Daylight Saving Time. See also “Show timezone command” on page 65 Modify user command Adds the specified user to the specified group and/or changes the password defined for the specified user. The groups defined for the DPM are Administrator and Monitor.
Syntax quit See also “Exit command” on page 32 Reboot command Restarts the Data Path Module. Syntax reboot Remove image command Removes an image. Syntax remove image [image-name] Keyword values [image-name] Name of image See also “Install image command” on page 34 “Show image command” on page 58 “Show images command” on page 58 Rescan command Rescan for new devices. Syntax rescan Reset debug command Resets the kernel module debug levels to their previously installed values.
reset debug level [module] Keyword values [module] Kernel module that will specifically have its debug level reset. If no value is specified (reset debug), then all debug levels for all modules are reset. See also “Create debug command” on page 18 “Load debug command” on page 34 “Save debug command” on page 46 “Set debug command” on page 46 “Show debug command” on page 51 Reset port command Shuts down the port and then restarts it, leaving the properties of the port unchanged.
Restart ntp command Stops and then restarts the ntp service. Syntax restart ntp See also “Disable ntp command” on page 24 “Enable ntp command” on page 29 “Modify ntp command” on page 38 “Show ntp command” on page 59 Restart snmp command Stops and then restarts the Simple Network Management Protocol.
Save config command Saves a configuration file. Syntax save config [name] Keyword values [name] Name of configuration file. See also “Delete config command” on page 20 “Load config command” on page 34 “Show configs command” on page 50 Save debug command Save the current debug state for all the kernel modules. These values can be restored later using the load debug command.
Keyword values [module name] Kernel module where the debug values will be set. [level value] New level to be set. [type-list] Comma-separated list of types to be set. Examples show debug modules fcpt returns: fctp=err (newcmd,iocomp,tmf,abts,puntrsp,quefull,rsp,dump) set debug fcpt level warning sets the fctp module level value to warning.
Syntax set eth [interface name] link [auto | duplex | speed ] or set eth [interface name] [family] [method] Keywords and values Description of keywords: [interface name] Ethernet interface that you are changing: MGMT, GE1, GE2, or GE3. link [auto] Auto negotiate duplex and link speed link [duplex ] Full or half link [speed ] 10, 100, or 1000.
See also “Enable bootset command” on page 27 “Show bootsets command” on page 49 Show bootsets command Displays the platform, version, status, checksum, and active status of all the bootsets. Syntax show bootsets See also “Enable bootset command” on page 27 “Show bootset command” on page 48 Show chassis command Returns the name, location, part number, MAC base address, serial number, original manufacture date, Fibre Channel World Wide Node Name, Fibre Channel maximum frame size, or rank for the DPM.
Maximum size of a Fibre Channel frame that can be sent or received by this DPM. Typically 2 k, should be set to the smallest frame size of any connected device. [name] Host name for this DPM. [orig_mfg_date] Indicates the original manufacturing date for this DPM. [part_num] Indicates the part number of the DPM. Use it to determine the original equipment manufacturer or manufacturing information about the switch. [rank] Controller rank for this DPM, such as “Primary” or “Secondary.
Syntax show copyright Show date command Returns the current date, time, and the time zone. Syntax show date See also “Modify date command” on page 36 Show debug command Returns information that may be helpful to HP support engineers in debugging a problem. There are currently three different forms of the show debug command. The first form allows you to look at various types of diagnostic data. The second form (show debug modules) allows you to look at the current debug settings for kernel modules.
Shows cumulative system debug information. [fcptstate] Provides the state of the SCSI target driver. [fcsdb] Shows information about the Fibre Channel ports and SCSI LUNs visible to the DPM. [fcsexch] Provides per port Fibre Channel Services (FCS) exchange allocation diagnostic. Used by support personnel. [fcsluns] FCS LUN discover. Local port database of remote ports with LUNs per remote port. [fcsstate] Provides a summary table showing how many targets, LUNs, and initiators are discovered by each port.
[modules] Provides a list of the loaded kernel modules. [ppeinfo] Shows firmware status. [pscs] Provides a list of the physical storage containers (PSCs) registered by the application. [pscstats] Provides statistics for each PSC registered by the application, such as total reads and writes issued on the PSC by the DPM software. [scsi] Provides information about all SCSI devices (Fibre Channel LUNs) visible to the DPM.
Notes As this command returns a large amount of information to the screen, turn on logging in your terminal program so that you can capture all the information in a file to send to HP. Examples show debug modules cssdev will return a line that looks like: cssdev=err (ucmd) which indicates that the kernel module cssdev has a debug level set to err. There is one extra type ucmd that can have different debug level set in cssdev. Show debug sac initiators will display initiator information from the sac.
Show eths command Returns the configuration—IP address, subnet mask, MAC base address, and gateway—for the four Ethernet interfaces: MGMT, GE1, GE2, or GE3. Syntax show eths See also “Disable eth command” on page 22 “Enable eth command” on page 27 “Modify eth command” on page 36 “Set eth command” on page 47 “Show eth command” on page 54 Show events command Reads the SOAP event log and displays the number of entries requested.
Syntax show fan [fan number] * Keyword values [fan number] An integer between 1 through 10, inclusive. * indicates all fans. Notes If the fan is a power supply fan, the RPM is not available. The RPM displays as 0 if the fan is not operational; as 1 if the fan is operational. See also “Show fans command” on page 56 Show fans command Displays the fan location, the status (either OK or Error), and the RPM for all fans in the DPM.
Show group command Returns the list of user names that belong to the specified group name. The groups defined for the DPM are Administrator and Monitor. Syntax show group [group name] Keyword values [group name] Name of the group to which users belong: Administrator or Monitor. Show groups command Returns a list of the users assigned to each group that is defined for this DPM. The groups defined for the DPM are Administrator and Monitor.
Show image command Displays the name, version, description, filename, and md5sum of the image specified. Syntax show image [image] Keyword values [image] Name of image. See also “Install image command” on page 34 “Remove image command” on page 43 “Show images command” on page 58 Show images command Displays the name, version, description, filename, and md5sum for all images.
Show log command Displays the contents of a log file. Syntax show log [logfile] Keyword values [logfile] Name of log file to be displayed. See also “Watch log command” on page 68 Show ntp command Displays the status of NTP for all regular and broadcast messages. Also shows the NTP server name and state of the NTP service.
* indicates all Fibre Channel ports on the DPM. Examples Here is a sample output for port 1 on a system after running show port 1.
10 11 12 13 14 15 NO-SIGNAL NO-SIGNAL NO-SIGNAL NO-SIGNAL NO-SIGNAL NO-SIGNAL TARG INIT TARG INIT TARG INIT FABRIC/UNSET FABRIC/UNSET FABRIC/UNSET FABRIC/UNSET FABRIC/UNSET FABRIC/UNSET NEG/UND NEG/UND NEG/UND NEG/UND NEG/UND NEG/UND 2048 2048 2048 2048 2048 2048 See also “Disable port command” on page 24 “Enable port command” on page 29 “Modify port command” on page 38 “Modify ports command” on page 39 “Reset port command” on page 44 “Show port command” on page 59 Show ps command Returns the status
Syntax show pss Notes When looking at the fan side of the DPM, power supply 1 is on the right side, and power supply 2 is on the left side. See also “Show ps command” on page 61 Show rport command Displays information for all ports matching the partial value of the WWPN specified. Syntax show rport [partial-name] Keyword values [partial-name] String of digits from the WWPN to match on.
See also “Create snmp command” on page 19 “Disable snmp command” on page 25 “Enable snmp command” on page 30 “Modify snmp command” on page 40 Show ssh command Indicates whether or not ssh is enabled or disabled. Syntax show ssh See also “Disable ssh command” on page 26 “Enable ssh command” on page 31 “Restart ssh command” on page 45 Show status command Returns the current status of all power supplies, fans, thermometers, and voltages for the DPM, and reports errors where detected.
Show telnet command Enables use of the telnet application to connect to the DPM CLI. Syntax show telnet See also “Disable telnet command” on page 26 “Enable telnet command” on page 31 Show therm command Returns the status, current temperature in Celsius and Fahrenheit, and the minimum and maximum thresholds for the specified thermometer. The DPM has six thermometers. Syntax show therm [therm number] * Keyword values therm number An integer between 1 and 6, inclusive.
Show timezone command Shows the time zone configuration settings for this DPM. Use the “Modify timezone command” on page 41 to change the settings. Syntax show timezone Notes Once the time zone is set, the system automatically switches between Standard Time and Daylight Saving Time. See also “Modify timezone command” on page 41 Show user command Returns the name of the group to which the specified user belongs and whether the user is enabled.
“Enable user command” on page 32 “Modify user command” on page 42 “Show groups command” on page 57 “Show user command” on page 65 Show version command Shows the firmware version number. Syntax show version Show version_number command Shows the firmware version number. Syntax show version_number Show voltage command Returns the nominal and actual voltages for the DPM. The nominal voltage is the expected voltage when everything is operating correctly. The actual voltage is the current voltage.
Syntax show voltages See also “Show voltage command” on page 66 Shutdown command Powers off the DPM. Syntax shutdown Version command Returns the DPM version. Syntax version Watch debug command Monitors activity of processes. Ctrl-C returns control to the CLI. Syntax watch debug [process] Keyword values [process] Process to monitor. (For a full list, enter watch debug.
Watch log command Monitors log activity. Ctrl-C returns control to the CLI. Syntax watch log [log-name] Keyword values [process] Log to monitor. (For a full list, enter watch log.
4 Using the Data Path Module management GUI The DPM Management GUI is supported on Microsoft Windows platforms running Internet Explorer version 5 or greater. To run the DPM Management GUI, install Java WebStart on your management station. Java WebStart is an application that allows you to download and run a full-featured Java application, such as the DPM Management GUI, directly from a web page.
2. In the screen that displays, click the version for Windows, local copy to install and run the Sun Java WebStart application on your machine. 3. On the Security Warning window, click Run. NOTE: You may need to manually download and install Java 1.5 or later before installing the VSM client interface. 4. The License Agreement dialog box is displayed. In the License Agreement dialog box, click Accept to begin software installation. 5. Click Start. 6. Click Yes if you want a desktop shortcut. 7.
Downloading the DPM Management GUI NOTE: At least 100 MB of free disk space must be available on the hard drive of your host system for the DPM Management GUI and WebStart software. Install WebStart from the browser used to access the DPM Management GUI. For example, you cannot install WebStart using Netscape and run the DPM Management GUI from Internet Explorer. 1. In your web browser, type the IP address of the DPM management port, labeled MGMT (for example, http://10.0.0.1).
Logging into the DPM Management GUI 1. From a web browser, log in with the username and password, using the same web browser from which the WebStart application was installed. User name: admin Password: password Figure 5 DPM Management GUI Login screen . 2. Click Login. 3. HP recommends that you change the password if you did not already do so during setup: • If you are using the DPM Management GUI, change the password on the telnet screen. See “Telnet” on page 81 for more information.
Figure 6 DPM Management GUI screen . Using the DPM Management GUI, you can access these functions.
3. Click the specific port to manage. The port information screen is displayed (see Figure 7). Figure 7 System port information screen . The following information is displayed for each selected port: • • • • • • • World Wide Node Name World Wide Port Name State of link (enabled/disabled) Mode (fabric or loop): Only fabric is supported with SVSP.
NOTE: Enabling and disabling ports takes effect immediately after clicking the Enable/Disable buttons. Disable: Click Disable to disable a port. Enable: Click Enable to enable a port. Chassis panel (system) The Chassis panel displays information about the DPM, such serial number and hardware versions. You can also set the description of the DPM and add a location comment. The DPM can also be rebooted from the Chassis panel.
Figure 9 System Ethernet panel . An amber LED indicates that the corresponding component is missing, has failed, or will likely fail soon. Even if your DPMs appear to be performing normally, replace the part if the corresponding LED has turned amber. SNMP panel (system) Figure 10 shows the SNMP panel. This panel allows SNMP v2 or v3 to be enabled or disabled. A trap receiver can also be specified that will receive SNMP trap events from the DPM, if not enabled during the initial installation.
Figure 10 System SNMP panel . Network Protocols panel (system) The Network Protocols panel allows the configuration of networking options on the Data Path Module. Figure 11 shows the Network Protocols panel. Figure 11 System Networks Protocols panel .
NOTE: If maximum network security is required, all the settings on this panel should be turned off in normal operation, and enabled only when needed. Enable SSH: Enables Secure Shell (SSH) support in the DPM. SSH is a remote login facility (similar to telnet) with security features, including strong encryption and authentication. Use SSH as a alternative to telnet for administrative logins to the DPM. To be useful, the client machines used for administrative access must be running as SSH client application.
Software panel (system) The Software panel shows the current and backup bootset information. Figure 13 System Software panel . Sensors panel (system) The Sensors panel for the System function shows diagnostic information for temperatures, fans, power supplies, and voltages for the power supplies on the Data Path Module. To view the Sensors panel, click Sensors in the tree hierarchy on the left. Figure 14 shows the System Sensors panel.
Figure 14 System Sensors panel . Diagnostics function The Diagnostics screen provides statistics for various aspects of the system. To use the Diagnostics panel: 1. Select an object type: 2. • Ports • Software • Licenses • System • Sensors Select a value for the object, such as port number if the object is a port.
3. Select a variable to graph. For example: utilization, errors, and transmit frames are among the variables that you can graph for a port on the Diagnostics screen. Figure 15 shows utilization for ports 4 and 8. Figure 15 Diagnostic screen displaying port utilization . Telnet function The telnet panel enables you to initiate a telnet session from the DPM Management GUI. To begin a telnet session from the DPM Management GUI: 1. Click Telnet in the left-most pane. 2.
Reconnect Telnet: Re-establishes a telnet session. Disconnect Telnet: Disconnects a telnet session. Log function Click Log in the left-most pane. The Log panel shows a list of system events (see Figure 17). Figure 17 Diagnostic screen log panel .
5 Support and other resources Contacting HP Before you contact HP Be sure to have the following information available before you contact HP: http://www.hp.
Related documentation The following documents provide related information: • HP StorageWorks • HP StorageWorks Guide • HP StorageWorks • HP StorageWorks SAN Virtualization Services Platform Manager User Guide SAN Virtualization Services Platform Manager Command Line Interface User SAN Virtualization Services Platform Administrator Guide SAN Virtualization Services Platform Release Notes You can find the documents on the Manuals page of the HP Business Support Center website: http://www.hp.
Document conventions and symbols Table 4 Document conventions Convention Element Blue text: Table 4 Cross-reference links and e-mail addresses Blue, underlined text: http://www.hp.
Product warranties For information about HP StorageWorks product warranties, see the warranty information website: http://www.hp.com/go/storagewarranty HP websites For additional information on HP storage products, see the following HP websites: • • • • • http://www.hp.com http://www.hp.com/go/storage http://www.hp.com/go/svsp http://www.hp.com/support/manuals http://www.hp.com/support/downloads Documentation feedback HP welcomes your feedback.
Glossary This glossary defines acronyms and terms used with the SVSP solution. access path A specific series of physical connections through which a device is recognized by another device. active boot set The boot set used to supply system software in a running system. Applies to the DPM. See also boot set. active path A path that is currently available for use. See also passive path, and in use path.
Business Copy SVSP An HP StorageWorks product that works with SAN storage systems to provide local replication capabilities within the SVSP domain, providing local point-in-time (PiT) copies of data, using snapshots of data, based on changes to virtual disks. CLI Command line interface. The Data Path Module provides a CLI through the local administrative console (serial port console), telnet, or SSH.
Group In VSM, a virtual container that defines one or more elements for a data moving task. See also VDG. HBA See host bus adapter. host In VSM, every server that uses VSM virtual disks. Servers that run as VSM servers are also considered hosts. host bus adapter A device that provides input/output (I/O) processing and physical connectivity between a server and a storage system.
Unit Number), which allows servers to access that particular logical unit. LUNs that a storage system exposes to the SVSP domain are identified by VSM as back-end LUs. migration A VSM service that migrates virtual disks from one storage pool to another while the host application remains online. mirror A VSM service that mirrors virtual disks synchronously and asynchronously. See also asynchronous mirroring and synchronous mirroring.
Each quad contains two front or host-facing ports, and two back or storage ports. Each of these ports is capable of a 4 Gbit/s Fibre Channel rate. Therefore, using additional quads may be necessary as a multiple of that 8 Gbit/s or 6.4 MB/s rate. RPO Recovery Point Objective. The point in time to which you must recover data as defined by your organization. This is generally a definition of what an organization determines is an acceptable loss in a distressed situation. RTO Recovery Time Objective.
synchronous mirroring A mode of data mirroring in which the updates on the mirror site are synchronized between destinations. system software image A software component, capable of being updated, that contains the operating environment for the Data Path Module, including the SVSP VSM agent for the Data Path Module. target Receives commands from the initiator, and after execution, returns acknowledgement to the initiator. See also initiator.
Volume Shadow Copy Service A backup infrastructure for the Microsoft Windows Server 2003/2008 operating systems, as well as a mechanism for creating consistent point-in-time copies of data known as shadow copies. VSM Virtualization Services Manager. Short for the HP StorageWorks SAN Virtualization Services Platform Manager application. VSM API virtual disk A virtual disk that enables a host to direct VSM CLI commands to a VSM server through a DPM.
Glossary