HP StorageWorks SAN Virtualization Services Platform Data Path Module User Guide (5697-0772, November 2010)

10 NO-SIGNAL TARG FABRIC/UNSET NEG/UND 2048
11 NO-SIGNAL INIT FABRIC/UNSET NEG/UND 2048
12 NO-SIGNAL TARG FABRIC/UNSET NEG/UND 2048
13 NO-SIGNAL INIT FABRIC/UNSET NEG/UND 2048
14 NO-SIGNAL TARG FABRIC/UNSET NEG/UND 2048
15 NO-SIGNAL INIT FABRIC/UNSET NEG/UND 2048
See also
Disable port command on page 24
Enable port command on page 29
Modify port command on page 38
Modify ports command on page 39
Reset port command on page 44
Show port command on page 59
Show ps command
Returns the status (Error or OK) and voltage information for the specified power supply. The DPM
arrives with two power supplies already installed.
Syntax
show ps
[power supply number]
*
Keyword values
[power supply number]
1 or 2.
* indicates both power supplies.
Notes
When looking at the fan side of the DPM, power supply 1 is on the right side, and power supply 2
is on the left side.
See also
Show pss command on page 61
Show pss command
Returns the status (Error or OK) and voltage information for each of the two power supplies on the
DPM.
HP StorageWorks SAN Virtualization Services Platform Data Path Module User Guide 61