HP StorageWorks SAN Virtualization Services Platform 2.02 release notes (5697-8024, February 2009)

An SNMP trap is not generated when power is removed from redundant PCM
When a single PCM fails, no SNMP trap is generated. This is a condition that should trigger an alert
to the administrator. HP is working to resolve this issue.
Cannot disable SNMP daemon
The default show debug dump command attempts to output several binary files to the console. This
results in unreadable output. The default output set is appropriate for saving to a file (for example,
create debug dump), but not for terminal output. Using show should use a different set of
parameters to the underlying script to generate only text output. HP is working to resolve this issue.
Order of magnitude of Tx/Rx Kbytes not correct with show ports stats command
The Tx Kbytes and Rx Kbytes statistics are not output correctly for the show ports stats command.
HP is working to resolve this issue.
The ‘%’ option of the show log command moves to the end of the file
The in-editor help display states you should press the % option, then enter a percentage. Instead of
moving to a percentage of the file, the % option of the show log command will always jump to the
end of the file. Instead, you should enter a percentage value and then press %.
VSM creates HBAs and host entries for a Brocade switch
Due to the fabric name server logging into the DPM as an initiator, the switch can sometimes show
up in the VSM as an HBA. The DPM should filter out switch ports so they are not presented to the
VSM. This has no practical effect, but may be confusing. HP is working to resolve this issue.
VSM CLI issues
Incorrect error message displayed with CreateSnapshotWithLun command
When running the CreateSnapshotWithLun command on a LUN that was already used, the message
Selected LUN is in the range that belongs to the host in another domain
is displayed instead of the message The Specified LUN is already used by this host.
HP is working to resolve this issue.
Incorrect error message displayed with -UsePreviousTemplateSuffix parameter
When running a CLI command with the -UsePreviousTemplateSuffix parameter, an error is displayed
even though the command was executed successfully. HP is working to resolve this issue.
Incorrect error message when ExpandVirtualDisk command is missing argument
When the ExpandVirtualDisk command is missing the MBfromPool argument, the error message
incorrectly states that the StoragePool name is missing. The error message should indicate that Not
all sizes specified for all StoragePools. HP is working to resolve this issue.
HP StorageWorks SAN Virtualization Services Platform 2.02 release notes 15