HP StorageWorks SAN Virtualization Services Platform Data Path Module user guide (5697-8058, March 2009)

Notes
If you are connected through the management port, modifying the MGMT Ethernet terminates any
active network GUI and CLI sessions, requiring a re-login through the serial or MGMT port. If you are
using the CLI on the serial console, the connection is not disrupted.
See also
Disable eth command” on page 26
Enable eth command” on page 31
Set eth command” on page 51
Show eth command” on page 58
Show eths command” on page 58
Modify factory command
Restore the factory rank or the factory WWNN value.
Syntax
modify factory rank [rank-value]
modify factory wwnn [wwnn-value]
Keyword values
At least one of the optional keywords is required:
[rank-value]
New rank value (Primary or Secondary).
[wwnn-value]
New WWNN to set.
See also
Load factory command” on page 38
Show factory command” on page 59
Modify ntp command
Change the NTP server.
Syntax
modify ntp server [server-name]
Keyword values
[server-name]
New server to be used to get the time.
HP StorageWorks SAN Virtualization Services Platform Data Path Module user guide 41