HP StorageWorks SAN Virtualization Services Platform Data Path Module user guide (5697-8058, March 2009)

Modify therm command
Sets the maximum or minimum temperature thresholds allowed for the thermometer specified.
Syntax
modify therm [number] maximum [max-temp] minimum [min-temp]
Keyword values
[number]
Thermometer number (in the range 0–6)
[max-temp]
Maximum temperature threshold (in Centigrade)
[min-temp]
Minimum temperature threshold (in Centigrade)
See also
Show therm command” on page 67
Show therms command” on page 68
Modify timezone command
Starts a Time Zone Configuration utility that enables you to select your geographical area and time
zone, and modify your local time, if needed.
Syntax
modify timezone [zone]
Keyword values
[zone]
Your time zone, for example, “EST,” “GMT,” “Japan,” and so on. Type modify timezone for a
full list of possible values.
Notes
Once the time zone is set, the system automatically switches between Standard Time and Daylight
Saving Time.
See also
Show timezone command” on page 68
HP StorageWorks SAN Virtualization Services Platform Data Path Module user guide 45