HP StorageWorks SAN Virtualization Services Platform 2.02 release notes (5697-8024, February 2009)

Incorrect error message when ManageSnapcloneGroup command is missing the Opcode
argument in HP-UX
If the Opcode argument is missing from the ManageSnapcloneGroup command in HP-UX, you will
receive an incorrect error message stating that both parameters are missing, instead of only the
Opcode missing. HP is working to resolve this issue.
The CreateSnapcloneGroupEx command fails with HP-UX if the group is still building
The CreateSnapcloneGroupEx command should run the first time. However, with HP-UX, if the
command is run again while the snapclone operation is still building the copy, the command fails.
You should increase the timeout argument to as long as you believe the building operation should
last. HP is working to resolve this issue.
The CreateSnapshotWithLun command fails to get last PiT instance for Pit26 with HP-UX
In HP-UX, use the SetUDHVirtualDiskLun command to change the snapshot LUN number. HP is
working to resolve this issue.
Do not use DeleteVirtualDisk command with LastInstance argument in HP-UX
In HP-UX, the use of the LastInstance argument with the DeleteVirtualDisk command is not
supported at this time. HP is working to resolve this issue.
Error with DeleteVirtualDisk command when virtual disk LUN number is out of range
When deleting a virtual disk with the DeleteVirtualDisk command, and the LUN number is out
of range, you will receive a SCSI I/O error message. This is expected behavior.
The CreateAsyncMirrorGroupEx command cannot be run in Linux
At this time, the CreateAsyncMirrorGroupEx command cannot be run in Linux. HP is working to
resolve this issue.
Virtual disk not added to async mirror group with
AddDiskToVirtualDiskGroupWithAsyncMirror command
With the AddDiskToVirtualDiskGroupWithSyncMirror command, a disk can be added to
a virtual disk group that has an asynchronous mirror, but an error message is received, and the disk
is not added to the asynchronous mirror group. The workaround is to perform this task with the VSM
GUI. HP is working to resolve this issue.
Published documentation issues
In the HP StorageWorks SAN Virtualization Services Platform installation and configuration guide,
the first graphic on page 108 for creating a virtual disk is not up-to-date. The correct graphic is
shown on page 99 (Figure 22) of the HP StorageWorks SAN Virtualization Services Platform
Manager user guide. Two check boxes were added to the screen. Use the Clustered (for Service
Guard running under Linux or HP-UX only) check box for LUN creation. Use the ThinProvision
HP StorageWorks SAN Virtualization Services Platform 2.02 release notes 17