Chapter 6228
Additional Parameters Used Only by Legacy Packages
IMPORTANT The following parameters are used only by legacy packages. Do not try to
use them in modular packages. See“Creating the Legacy Package
Configuration” on page 275 for more information.
PATH Specifies the path to be used by the script.
SUBNET Specifies the IP subnets that are to be monitored for
the package.
RUN_SCRIPT and HALT_SCRIPT
Use the full pathname of each script.
These two parameters allow you to separate package
run instructions and package halt instructions for
legacy packages into separate scripts if you need to. In
this case, make sure you include identical configuration
information (such as node names, IP addresses, etc.) in
both scripts.
In most cases, though, HP recommends that you use
the same script for both run and halt instructions.
(When the package starts, the script is passed the
parameter start; when it halts, it is passed the
parameter stop.)
LV The name of a logical volume hosting a file system that
will be mounted by the package.
FS The name of the mount point for a file system to be
mounted by the package.
VGCHANGE As vgchange_cmd (see page 221).