HP Smart Update Manager 6.0.1 Release Notes (Ed. 3)

Report issues
HP SUM does not generate reports for QLogic Fibre Channel switch
Suggested Action: No action. This is a known issue that will be resolved in a future version of HP SUM.
HP SUM does not generate reports for HP-UX nodes
Suggested Action: No action. This is a known issue that will be resolved in a future version.
HP SUM does not generate CSV reports correctly
Suggested Action: Generate reports in HTML or XML format.
HP SUM displays the session ID, not the node name, on the Activity screen when generating a report
Suggested Action: No action necessary. This will be fixed in a future version.
Help issues
HP SUM does not display the online help on the Deploy screen when you select multiple nodes
Suggested Action: Do not open the help from the Deploy screen when you have multiple nodes selected.
HP SUM legacy CLI documentation includes incorrect information about the /oa_username attribute
Suggested Action: Use the /oa_username and /oa_password attributes even if the OA and VC
use the same credentials.
This argument provides the user name credential for OA
associated with VC specified with the target command-line
/oa_username
parameter. Only one set of OA credentials can be specified
with command-line parameters. You can add multiple VC
nodes to command-line parameters with the target
parameter only if the credentials of OAs associated with
specified VCs are the same. You do not need to provide an
OA network address associated with VC. HP SUM queries
it from a specified VC node.
To update multiple VCs with different user names and
passwords, or VCs with OAs that have different credentials,
use the corresponding input files OAUID and OAPWD.
Provides the password credential for OA associated with VC
specified with the "node" command-line parameter. Only
/oa_password
one set of OA credentials can be specified with command-line
parameters. You can add multiple VC nodes to command-line
parameters with the "node" parameter only if the credentials
of OAs associated with specified VCs are the same. You do
not need to provide an OA network address associated with
VC. HP SUM queries it from a specified VC node.
To update multiple VCs with different user names and
passwords, or VCs with OAs that have different credentials,
use the corresponding input files OAUID and OAPWD .
This command is not working correctly. This will be resolved
in a future version.
/romonly
HP SUM legacy CLI documentation includes incorrect information about the /dryrun attribute
Suggested Action: HP SUM legacy CLI mode supports the /dryrun parameter. The documentation
will be corrected for a future release.
Issues and suggested actions 23