Building Disaster Tolerant Serviceguard Solutions Using Metrocluster with Continuous Access XP
Preparing the Cluster for Data Replication
Chapter 3174
# export HORCMPERM=/etc/horcmperm0.conf
If the Raid Manager protection facility is not used or disabled, export
the HORCPERM environment variable.
# export HORCMPERM=MGRNOINST
8. Start the Raid Manager instance by using horcmstart.sh
<instance-#>.
# horcmstart.sh 0
9. Export the environment variable that specifies the Raid Manager
instance to be used by the Raid Manager commands. For example,
with the POSIX shell type.
# export HORCMINST=0
Now, use Raid Manager commands to get further information from
the disk arrays.
To verify the software revision of the Raid Manager and the
firmware revision of the XP disk array.
# raidqry -l
NOTE Check for the minimum requirement level for XP, Raid Manager
software, and firmware for your version listed in the Metrocluster
Continuous Access XP Release Notes.
To view a list of the available devices on the disk arrays.
# raidscan
The above command must be invoked separately for each host
interface connection to the disk array. For example, if there are two
Fibre Channel host adapters.
# raidscan -p CL1-A
# raidscan -p CL1-B