Designing Disaster Tolerant High Availability Clusters, 10th Edition, March 2003 (B7660-90013)

Building a Metropolitan Cluster Using MetroCluster/SRDF
Preparing a Cluster for MetroCluster/SRDF
Chapter 4148
1. Obtain a list of data for the Symmetrix devices available, using the
following command on each node without any options:
# syminq
Sample output from both the R1 and R2 sides is shown in
Figure 4-13 and Figure 4-14.
Figure 4-13 Sample syminq Output from a Node on the R1 Side
Figure 4-14 Sample syminq Output from a Node on the R2 Side
Device Product
Name Type Vendor ID Rev Ser Num Cap(KB)
/dev/rdsk/c0t0d0 R1 EMC Symmetrix 5264 95004160 4418880
/dev/rdsk/c0t0d1 R1 EMC Symmetrix 5264 95005160 4418880
/dev/rdsk/c0t0d2 R2 EMC Symmetrix 5264 95006160 4418880
/dev/rdsk/c0t0d3 R2 EMC Symmetrix 5264 95007160 4418880
/dev/rdsk/c0t1d0 BCV EMC Symmetrix 5264 95024160 4418880
/dev/rdsk/c0t1d1 BCV EMC Symmetrix 5264 95025160 4418880
/dev/rdsk/c0t1d0 GK EMC Symmetrix 5264 95040160 2880
/dev/rdsk/c0t1d1 GK EMC Symmetrix 5264 95041160 2880
/dev/rdsk/c0t1d2 GK EMC Symmetrix 5264 95042160 2880
/dev/rdsk/c1t2d0 R1 EMC Symmetrix 5264 95004320 4418880
/dev/rdsk/c1t2d1 R1 EMC Symmetrix 5264 95005320 4418880
/dev/rdsk/c1t2d2 R2 EMC Symmetrix 5264 95006320 4418880
/dev/rdsk/c4t0d0 R2 EMC Symmetrix 5264 50014321 4418880
/dev/rdsk/c4t0d1 R2 EMC Symmetrix 5264 50015321 4418880
/dev/rdsk/c4t0d2 R1 EMC Symmetrix 5264 50016321 4418880
/dev/rdsk/c4t0d3 R1 EMC Symmetrix 5264 50017321 4418880
/dev/rdsk/c4t1d0 BCV EMC Symmetrix 5264 50034321 4418880
/dev/rdsk/c4t1d1 BCV EMC Symmetrix 5264 50035321 4418880
/dev/rdsk/c4t1d0 GK EMC Symmetrix 5264 50040321 2880
/dev/rdsk/c3t1d1 GK EMC Symmetrix 5264 50041321 2880
/dev/rdsk/c3t1d0 BCV EMC Symmetrix 5264 50030161 4418880
/dev/rdsk/c3t1d1 BCV EMC Symmetrix 5264 50031161 4418880
/dev/rdsk/c3t3d0 R2 EMC Symmetrix 5264 50004161 4418880
/dev/rdsk/c3t3d1 R2 EMC Symmetrix 5264 50005161 4418880
/dev/rdsk/c3t3d2 R1 EMC Symmetrix 5264 50006161 4418880
Device Product
Name Type Vendor ID Rev Ser Num Cap(KB)