HP Serviceguard Extended Distance Cluster for Linux A.01.01 Deployment Guide, Third Edition, May 2008

Migrating to HP Serviceguard A.11.18
Configuring Modular Packages for Extended Distance Cluster Software
Chapter 490
# of the component mirror disks.
# The default value of "raid_monitor_interval" is set to 30 seconds.
# Legal values for raid_monitor_interval: (value > 0).
raid_monitor_interval 30
# "raid_device" is used to specify the mirror devices that are used by
# this package.
# "device_0" and "device_1" are used to specify the first and the second
# mirror components of the mirror device "raid_device".
# The keywords "raid_device", "device_0" and "device_1" are used to specify
# a mirror device and its two component devices. Enter these three parameters
# for each mirror device that this package will use.
#
# The value for "raid_device" is the name of the md mirror device.
# The value for "device_0" is the name of the first component mirror half of
# the mirror device defined in the "raid_device"
#
# The value for "device_1" is the name of the second component mirror half of
# the mirror device defined in the "raid_device"
# Note: Only persistent device names created using udev must be used as the
# names of the component mirror halves of the raid device.
# For example, if this package uses raid devices /dev/md0, having its first
# and second mirror component as /dev/hpdev/mylink-sda and
/dev/hpdev/mylink-sdc,
# and /dev/md1, having its first and second mirror component as
# /dev/hpdev/mylink-sdb and /dev/hpdev/mylink-sdd.
# enter:
# raid_device /dev/md0
# device_0 /dev/hpdev/mylink-sda
# device_1 /dev/hpdev/mylink-sdc
# raid_device /dev/md1