Serviceguard sets the environment variable SG_HALT_REASON in the package control
script to one of the following values when the package halts:
failure - set if the package halts because of the failure of a subnet, resource, or
service it depends on
user_halt - set if the package is halted by a cmhaltpkg or cmhaltnode
command, or by corresponding actions in Serviceguard Manager
automatic_halt - set if the package is failed over automatically because of the
failure of a package it depends on, or is failed back to its primary node automatically
(failback_policy = automatic)
You can add custom code to the package to interrogate this variable, determine why
the package halted, and take appropriate action. For legacy packages, put the code in
the customer_defined_halt_cmds() function in the CUSTOMER DEFINED
FUNCTIONS area of the package control script (see Adding Customer Defined Functions
to the Package Control Script ” (page 276)); for modular packages, put the code in the
package’s external script (see About External Scripts” (page 147)).
For example, if a database package is being halted by an administrator
(SG_HALT_REASON set to user_halt) you would probably want the custom code to
perform an orderly shutdown of the database; on the other hand, a forced shutdown
might be needed if SG_HALT_REASON is set to failure, indicating thatthe
package is halting abnormally (for example because of the failure of a service it depends
on).
last_halt_failed Flag
cmviewcl -v -f line displays a last_halt_failed flag.
NOTE: last_halt_failed appears only in the line output of cmviewcl, not the
default tabular format; you must use the -f line option to see it.
The value of last_halt_failed is no if the halt script ran successfully, or has not run
since the node joined the cluster, or has not run since the package was configured to
run on the node; otherwise it is yes.
About Cross-Subnet Failover
It is possible to configure a cluster that spans subnets joined by a router, with some nodes
using one subnet and some another. This is known as a cross-subnet configuration; see
“Cross-Subnet Configurations” (page 27). In this context, you can configure packages
to fail over from a node on one subnet to a node on another.