HP Serviceguard for Linux Version A.11.20.00 Deployment Guide, August 2012

6
Tip:
Do not connect the Fibre Channel cables to each server until after the OS
has been installed on each server, otherwise the OS installation process
may attempt to place the boot image on the external storage device.
Network Planning
The minimum network configuration requires two network connections (eth2 and eth3) configured as a
bonded pair running a heartbeat and the public network connections from each server. Each
network connection should be plugged into separate switches (see Figure 1). If three network
connections are used, one should be configured in a private heartbeat network (eth0, shown in grey
in Figure 1) and the other should be a bonded pair for the public and heartbeat networks. For more
details, see Managing HP Serviceguard for Linux manual.
Figure 1. Network and Storage Topology
Required Networking Information:
1. Get static IP Addresses for the following:
a. 2 IP addresses and hostnames with subnet mask, one for each server
b. 2 relocatable IP addresses (1 for consolidated logging package, 1 for sample
package), DNS names (optional) and subnet mask
c. 1 IP address, hostname, and subnet mask for management access to the external
storage device (storage)
d. Gateway address, DNS server address(es)
2. NTP Server (recommended but not required)
a. name and address of NTP server that will be reachable by the servers and
external storage device
clients
Network
Node 1
eth3
eth2
eth0
Node 2
eth3
eth2
eth0
Switch
bond0
bond0