HP Serviceguard for Linux Version A.11.19 Deployment Guide, September 2012

15
Plug in the Fibre Channel cables as follows:
1. Host 1 plug 2 Fibre Channel cables from the dual channel HBA to the MSA2000 to
a. Controller A Port 0
b. Controller B Port 0
2. Host 2 plug 2 Fibre Channel cables from the dual channel HBA to the MSA2000 to
a. Controller A Port 1
b. Controller B Port 1
Figure 2. Wiring the servers to the storage controllers for redundancy
Setting Management Port IP Address using the CLI
The IP address can be configured using the CLI (command line interface) from a serial console or
through DHCP.
To configure the IP address using the CLI, perform the following steps:
1. Plug the serial cable (Mini DB9 RS232 Serial cable) into the COM1 port of a PC to access
the MSA2000 via a terminal emulator such as HyperTerminal (available on most Windows
PCs) and into the serial port of one of the storage device controllers.
2. Run HyperTerminal from the PC. The settings are:
Terminal Emulation Mode: VT-100 or ANSI
Font: Terminal
Translations: None
Columns: None
Connector: COM1 (typically)
Baud rate: 115,200
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
NOTE: For more detailed information, refer to the MSA2000 CLI Reference Guide.
3. Once connected, press <Enter> to display the prompt (#).