Smart Array 5300 Controller User Guide

Installing the Hardware
4. Unplug the AC power cord from the outlet, and then from the server.
IMPORTANT: If you will be replacing an existing Smart Array controller with a Smart
Array 5300 controller, see the “External Cabling for HP Servers” section to determine the
external cabling requirements.
5. Disconnect any peripheral devices from the server.
WARNING: To reduce the risk of personal injury from hot surfaces, allow
the internal system components and hot-plug hard drives to cool before
touching them.
CAUTION: Electrostatic discharge (ESD) can damage electronic components.
Be sure that you are properly grounded before continuing the installation
procedure. Refer to Appendix B, “Electrostatic Discharge,” for ESD information.
Installing the Smart Array Controller
1. Remove or open the access panel.
2. Select an available 66-MHz PCI slot. Slots that use a 64-bit interface may
provide higher performance.
NOTE: In IPF servers, the ID number of the slot in which you insert the controller
determines the boot controller order. Follow the recommendations in the server-specific
documentation to obtain the required controller order.
3. Remove the slot cover or open the hot-plug latch. Save the retaining screw, if one
is present.
4. Slide the controller board along the slot alignment guide.
3-2 HP Smart Array 5300 Controller User Guide
HP CONFIDENTIAL
Writer: Kimberly Koch File Name: d-ch3 installing the hardware.doc
Codename: SilverHammer Part Number: 135606-006 Last Saved On: 3/13/03 1:54 PM