Designing Disaster Recovery Clusters using Metroclusters and Continentalclusters, Reprinted October 2011 (5900-1881)

When the parameter is set to 1, the monitor will send
notifications to the syslog file. If the parameter is not defined
(commented out), the default value is 0.
MON_NOTIFICATION_CONSOLE (Default = 0)
This parameter defines whether the monitor will send console
notifications. When the parameter is set to 0, the monitor
will NOT send console notifications. When the parameter
is set to 1, the monitor will send console notifications. If the
parameter is not defined (commented out), the default value
is 0.
AUTO_RESYNC This parameter defines the pre-defined resynchronization
actions that the monitor can perform when the package is
on the PVOL side and the monitor detects the Continuous
Access data replication link is down. If the variable is not
defined or commented, the default value of 0 is used.
Values:
0 — (Default) When the parameter is set to 0, the monitor
will not perform any resynchronization actions.
1 When the parameter is set to 1 and the data replication
link is down, the monitor will split the remote BC (if
configured) and try to resynchronize the device. Until the
resynchronization starts, the monitor will try to resynchronize
every polling interval. Once the device group has been
completely resynchronized, the monitor will resynchronize
the remote BC.
2 – When the parameter is set to 2 and the data replication
link is down, the monitor will only try to perform
resynchronization if a file named MON_RESYNC exists in the
package directory (PKGDIR). The monitor will not perform
any operations to the remote BC (that is, split and
resynchronize the remote BC). Therefore, this setting is used
when you want to manage the remote BC
Modular Package Sample Configuration file
$ cmmakepkg m dts/mcxpca v 1 temp.conf
mcxpcapkgpackage_name
"Metrocluster XPCA Package"package_description
sg/basicmodule_name
1module_version
dts/mcxpcamodule_name
1module_version
dts/mcmodule_name
1module_version
sg/volume_groupmodule_name
1module_version
sg/prioritymodule_name
1module_version
Modular Package Sample Configuration file 485