HP Serviceguard Storage Management Suite A.03.02 Release Notes (March 2012)

Unsupported Bundle Change and Installation Scenarios
Installing Storage Management Suite on top of HP Serviceguard Extension for RAC is not supported.
If you have the two as separate products, install the Storage Management Suite bundle T2776DB
first, then install HP Serviceguard Extension for RAC.
NOTE:
For current information on Serviceguard and HP-UX versions that are supported with various
SG SMS versions, see the HP Serviceguard/SGeRAC/Storage Management Suite/Serviceguard
Manager Plug-in Compatibility and Feature Matrix at: www.hp.com/go/hpux-serviceguard-docs
HP Serviceguard
Upgrades of “mixed OS” clusters (clusters that have some nodes running HP-UX 11i v2 and
other nodes running HP-UX 11i v3 ) are not supported with SG SMS bundles that include
CVM/CFS (T2775xx, T2776xx, T2777xx). For more information see the HP Serviceguard
Version A.11.20 Release Notes at: www.hp.com/go/hpux-serviceguard-docs HP
Serviceguard
HP Serviceguard Storage Management Suite Compatibility with HP-UX Releases
HP Serviceguard Storage Management Suite Version A.03.02 bundles are designated “TxxxxDB”
- they are compatible with HP-UX 11i v3 only.
NOTE: HP-UX 11iv3 is supported with up to 64k lunpaths, however, Veritas™ products included
in the SG SMS Version A.03.02 bundles limit SG SMS lunpath support to a maximum of 32k
lunpaths on HP-UX 11i v3.
System Requirements
HP Serviceguard Storage Management Suite bundles run on HP 9000 or HP Integrity Servers.
Using both types of servers in the same cluster is supported.
Disk Requirements
Installation of any HP Serviceguard Storage Management Suite bundle requires a minimum of 550
MB of disk space in the root file system.
Before Installing HP Serviceguard Storage Management Suite Version A.03.02
Before installing an HP Serviceguard Storage Management Suite bundle, consult with your HP
representative to make sure that the cluster has the correct hardware upgrades and supported
firmware revisions. Also check for any updated patch requirements for the software products being
installed.
Patches for HP products and Veritas™ products included in the HP Serviceguard Storage
Management Suite bundles can be downloaded at: http://www.hp.com/go/sgsms/patches
NOTE:
Before attempting a SG SMS bundle installation or upgrade, you must disable
AUTOSTART_CMCLD. See “Disabling Cluster Auto-Start on Reboot” (page 23)
SG SMS Version A.03.02 bundles cannot be installed over OnlineJFS 5.0 (B3929FB), which
is included with the HP-UX September 2009 OE Update Release for HAOE, DCOE and
VSE-OE. To install a SG SMS Version A.03.02 bundle, follow these steps:
1. Remove B3929FB. If the bundle is not found, remove
OnlineJFS01.VXFS50-AD-RN,r=5.0 and AONLINEJFS,r=B.05.00.01.
2. Install the SG SMS Version A.03.02 bundle.
26 HP Serviceguard Storage Management Suite Version A.03.02 for HP-UX 11i v3 Release Notes