HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008)

Appendix A SNMP Configuration 241
Configuring SNMP Event Notification in SMU
As a Manage user you can configure and enable SNMP event notification. To do so:
1. Select the level of events to include in the FA2.2 event table; see “Setting the SNMP
Event Table Filter” on page 50.
2. Verify that the storage system’s SNMP service is enabled; see “Configuring
Network Management Services” on page 52.
3. Select event levels for notification; see “Selecting Event Categories to Monitor” on
page 54.
4. Configure and enable SNMP traps; see “Configuring SNMP Traps” on page 58.
SNMP Management
You can manage storage devices using SNMP with a network management system
such as HP System Insight Manager (SIM) or HP Instant Support Enterprise Edition
(ISEE). See their documentation for information about loading MIBs, configuring
events, and viewing and setting group objects.
In order to view and set system group objects, SNMP must be enabled in the storage
system. To enable SNMP in SMU:
1. Select Manage > General Config > Services Security.
2. Set Simple Network Management Protocol (SNMP) to Enabled.
This setting is Enabled by default.
3. Click Update Network Management Services.