HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008)

278 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008
39 Warning The sensors monitored a temperature
or voltage in the warning range.
Check that the storage system’s
fans are running.
Check that the ambient
temperature is not too warm. The
enclosure operating range is
41° F to 104° F (5° C to 40° C).
Check for any obstructions to the
airflow.
If none of the above explanations
apply, replace the controller FRU
that reported the error.
When the problem is fixed, event
47 is logged.
40 Critical The sensors monitored a temperature
or voltage in the failure range.
Check that the storage system’s
fans are running.
Check that the ambient
temperature is not too warm. The
enclosure operating range is
41° F to 104° F (5° C to 40° C).
Check for any obstructions to the
airflow.
If none of the above explanations
apply, replace the controller FRU
that reported the error.
When the problem is fixed, event
47 is logged.
41 Informational A vdisk spare has been added.
43 Informational A vdisk has been deleted.
44 Warning The controller contains dirty cache
data for the specified volume but the
corresponding disk drives are not
online.
Determine the reason that the
drives are not online.
If an enclosure is down,
determine corrective action.
If the virtual disk is no longer
needed, you can clear the orphan
data; this will result in lost data.
TABLE E-1 Event Descriptions and Recommended Actions (Continued)
Event
Code Event Type Description Recommended Action