80 Informational The controller has modified mode
parameters on one or more drives.
81 Informational The current controller has unkilled
the partner controller. The other
controller will restart.
83 Informational The partner controller is changing
state (shutting down or restarting).
84 Warning In an active-active configuration, the
current controller has forced the
partner controller to fail over for the
specified reason.
Save the log files and review them
for other errors. A service
technician can determine errors
from the logs.
86 Informational The FC host port or drive parameters
have been changed.
87 Warning The mirrored configuration retrieved
by this controller from the partner
controller has bad cyclic redundancy
check (CRC). The local flash
configuration will be used instead.
The mirrored configuration is
corrupted. Configuration data on
the two controllers may be out of
sync. Clear configuration may be
needed to fully recover from this.
88 Warning The mirrored configuration retrieved
by this controller from the partner
controller is corrupt. The local flash
configuration will be used instead.
The mirrored configuration is
corrupted. Configuration data on
the two controllers may be out of
sync. Clear configuration may be
needed to fully recover from this.
89 Warning The mirrored configuration retrieved
by this controller from the partner
controller has a configuration level
that is too high for the firmware in
this controller to process. The local
flash configuration will be used
instead.
This likely indicates that the
current controller has down-level
firmware. Update the firmware on
the down-level controller. Both
controllers should have the same
firmware versions.
When the problem is fixed, event
20 is logged.
TABLE E-1 Event Descriptions and Recommended Actions (Continued)
Event
Code Event Type Description Recommended Action