HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008)

284 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008
107 Critical The controller experienced the
specified critical error. In a non-
redundant configuration the controller
will be restarted automatically. In an
active-active configuration the
surviving controller will kill the
controller that experienced the critical
error.
A service technician can use the
debug log to determine the
problem.
108 Informational A volume has been deleted.
109 Informational The statistics for the specified vdisk
have been reset.
110 Informational Ownership of the specified vdisk has
been given to the other controller.
111 Informational The link for the specified host port is
up.
112 Informational The link for the specified host port is
down. (Occurs after every LIP event.)
113 Informational The link for the specified disk
channel port is up.
114 Informational The link for the specified disk
channel port is down.
116 Critical After a recovery, the partner
controller was killed while mirroring
write-back data to the current
controller. The current controller
restarted to avoid losing the data in
the partner controller's cache, but if
the other controller does not restart
successfully, the data will be lost.
To determine if data might have
been lost, check whether this event
was immediately followed by
restart event 56, closely followed
by failover event 71 (specifying
p1=1).
118 Informational Cache parameters have been changed
for the specified vdisk.
TABLE E-1 Event Descriptions and Recommended Actions (Continued)
Event
Code Event Type Description Recommended Action