HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008)

286 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008
154 Informational New software has been loaded on the
Management Controller.
155 Informational New loader software has been loaded
on the Management Controller.
156 Informational The Management Controller has been
restarted from the Storage Controller.
157 Critical A failure occurred when trying to
write to the Storage Controller flash
chip.
Replace the controller module.
160 Warning The EMP enclosures are not
configured correctly. All enclosure
EMPs on that channel are disabled.
Check that EMP enclosures are
configured correctly and issue a
rescan.
161 Informational One or more enclosures do not have a
valid path to an EMP. All enclosure
EMPs are disabled.
162 Warning The host Fibre Channel World Wide
Names (node and port) previously
presented by this controller module in
this system are unknown. This event
has two possible causes:
One or both controller modules
have been replaced or moved while
the system was powered off.
One or both controller modules
have had their flash configuration
cleared (this is where the
previously used WWNs are stored).
The controller module recovers from
this situation by generating a WWN
based on its own serial number.
Verify the WWN information for
this controller module on all hosts
that access it.
TABLE E-1 Event Descriptions and Recommended Actions (Continued)
Event
Code Event Type Description Recommended Action