HP StorageWorks 2300 Modular Smart Array reference guide (500911-001, January 2009)

HP StorageWorks 2300 Modular Smart Array reference guide 105
7. If the updated disks must be power cycled:
a. Shut down both controllers by accessing the CLI and using the shutdown command. For details,
see your product’s CLI reference guide.
b. Power cycle all enclosures as described in your product’s user guide.
NOTE: If you loaded firmware to a Seagate 750-Gbyte Barracuda ES SATA drive, after spin-up it
will be busy for about 50 seconds completing its upgrade. Then it will be ready for host I/O.
8. In SMU, verify that each disk has the correct firmware revision.
9. Resume host I/O.