HP StorageWorks 2300 Modular Smart Array reference guide (500911-001, January 2009)

HP StorageWorks 2300 Modular Smart Array reference guide 81
-- Trap annotations are as follows:
--#TYPE "Error storage event"
--#SUMMARY "Error storage event # %d, type %d, description: %s"
--#ARGUMENTS {0,1,2}
--#SEVERITY MAJOR
--#TIMEINDEX 6
::= 3003
msaEventCriticalTrap TRAP-TYPE
ENTERPRISE hpMSA
VARIABLES { connUnitEventId,
connUnitEventType,
connUnitEventDescr }
DESCRIPTION
"An event has been generated by the storage array.
Recommended severity level (for filtering): critical"
-- Trap annotations are as follows:
--#TYPE "Critical storage event"
--#SUMMARY "Critical storage event # %d, type %d, description: %s"
--#ARGUMENTS {0,1,2}
--#SEVERITY CRITICAL
--#TIMEINDEX 6
::= 3004
END
FA MIB 2.2 and 4.0 Differences
FA MIB 2.2 is a subset of FA MIB 4.0. Therefore, SNMP elements implemented in 2300 Modular Smart
Array storage systems can be accessed by a management application that uses FA MIB 4.0.
The following tables are not implemented in 2.2:
connUnitServiceScalars
connUnitServiceTables
connUnitZoneTable
connUnitZoningAliasTable
connUnitSnsTable
connUnitPlatformTable
The following variables are not implemented in 2.2:
connUnitFabricID
connUnitNumLinks
connUnitVendorId
connUnitPortProtocolCap,
connUnitPortProtocolOp,
connUnitPortNodeWwn,
connUnitPortHWState
connUnitLinkCurrIndex