HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008)

160 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008
The status is OK when there are no critical or warning conditions for the element
type. If no enclosure polling data is available, a message is displayed stating this.
For information about a critical or warning condition, view the event log; see
“Viewing the Event Log” on page 171.
Controller Versions
You can view the software, hardware, and other version information for each
controller module. During normal operation, all software versions should be the
same on both controller modules. Software versions might differ briefly while you
are updating the firmware on each controller module.
To view version information:
Select Monitor > Status > Advanced Settings > Controller Versions.
Version information is displayed in the following four panels.
The Storage Controller Code Versions panel shows the following information:
Code Version – Storage Controller software version
Memory Controller – Memory controller software version
Loader Version – Storage Controller loader software version
The Management Controller Code Versions panel shows the following information:
Code Version – Management Controller software version
Loader Version – Management Controller loader software version
The Enclosure Controller Code Versions panel shows the Expander Controller
software version.
The RAID Controller Hardware Versions panel shows the following information.
Hardware Version – Board version number
CPU Type – Type of RAID controller processor:
Celeron 566MHz, used in a standard controller module
Pentium III 700MHz, used in an enhanced FC controller module
CPLD Version – Version of the complex programmable logic device (CPLD)
Host Interface Module Model – Model number of the host interface module
within a controller module
Host Interface Module Version – Version of the host interface module within a
controller module
Cache Memory Size – Cache memory size in Mbyte