HP StorageWorks 2000 Modular Smart Array Reference Guide (481599-003, August 2008)

184 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008
Scanning for Device Changes
Rescan forces rediscovery of attached disk drives and enclosures. If both storage
controllers are online, it also forces re-evaluation of the enclosure IDs of attached
drive enclosures, so that IDs are assigned based on controller As enclosure cabling
order. A manual rescan may be needed after system power-up to display enclosures
in the proper order.
A manual rescan is not required to detect when drives are inserted or removed; the
controllers do this automatically. When drives are inserted they are detected after a
short delay, which allows the drives to spin up.
When you perform a manual rescan, it temporarily pauses all I/O processes, then
resumes normal operation. It can take up to two minutes for the enclosure IDs to be
corrected.
To rescan, as an Advanced Manage user:
1. Verify that both controllers are up.
2. Select Manage > Utilities > Disk Drive Utilities > Rescan.
3. In the Rescan For Devices panel, click Rescan.